Festo VPPE F1A Series Скачать руководство пользователя страница 4

12

Technical data

Fig. 4: VPPE-3-1-1/8-2-... p1 = 0.4 MPa

Fig. 5: VPPE-3-1-1/8-6-... p1 = 0.8 MPa

Fig. 6: VPPE-3-1-1/8-10-... p1 = 1.1 MPa

Characteristic values

Design

Proportional-pressure regulator

Mounting position

As desired, preferably vertical (electronics upward).

Medium

[7:4:4]
Lubricated operation not possible

Pressure regulation range

[MPa]

0.002 … 0.2

0.006 … 0.6

0.01 … 1

Permissible input pressure
(Input pressure p1 min.
0.1 MPa above output pres-
sure p2)

[MPa]

0.3 … 0.4

0.6 … 0.8

0.6 … 1.1

Standard nominal flow rate

è

 Fig. 4 to 

è

 Fig. 6

Total leakage when new

[l/h]

<

 5

Ports

G 1/8

Nominal width

Pressurisation

[mm]

5

Exhaust port

[mm]

2.5

Degree of protection

IP65 in combination with connector socket according to
accessories

Permissible temperature range

Environment

[°C]

0 … +60

Storage

[°C]

–10 … +60

Medium

[°C]

+10 … +50

Electrical connection

Pin contact M12x1, 5-pin

Permitted supply voltage

24 V DC ± 10%

Setpoint variable

0 … 10 V/4 … 20 mA

Input resistance

10 kΩ (voltage) / 250 Ω (current)

Load actual value output

min. 2 kΩ (voltage)
max. 500 Ω (current)

Residual ripple

[%]

10

Vibration and shock

Vibration

Tested in accordance with DIN/IEC 68/EN 60068
Part 2-6,
Severity level 2

Characteristic values

Shock

Tested in accordance with DIN/IEC 68/EN 60068
Part 2-27,
Severity level 2

Power consumption

[W]

max. 4.2

Electromagnetic compatibility

EMC interference emission
and immunity to interference

See declaration of conformity

è

  www.festo.com

CE conformity for industrial installations fulfilled

Materials

Housing

Al

Cover

PA

Seals

NBR

Lubrication

silicone-free

Weight

[g]

390

Tab. 9: Characteristic values

Type of severity level (SL)

Vibration load
Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SL1

SL2

SL1

SG2

SL1

SL2

 8

 8

±

3.5

±

3.5

 27

 27

10

10

27 

 58

27 

 60

±

0.15

±

0.35

58 

 160

60 

 160

20

50

160 

 200

160 

 200

10

10

Shock load
Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SL1

SL2

SL1

SL2

SL1

SL2

±

150

±

300

11

11

5

5

Continuous shock load
Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

±

150

6

1000

Tab. 10: Type of severity level (SL)

Control characteristics

1)

Linearity

1% Full Scale (FS) at 24 V DC and 25 °C

Hysteresis

Pressure regulation range
0.002 MPa … 0.2 MPa

1% Full Scale (FS)

Pressure regulation range
0.006 MPa … 0.6 MPa

0.5% Full Scale (FS)

Pressure regulation range
0.01 MPa … 1 MPa

0.5% Full Scale (FS)

Reproducibility

0.5% Full Scale (FS)

Total accuracy

Pressure regulation range
0.002 MPa … 0.2 MPa

1.5% Full Scale (FS)

Pressure regulation range
0.006 MPa … 0.6 MPa

1.25% Full Scale (FS)

Pressure regulation range
0.01 MPa … 1 MPa

1.25% Full Scale (FS)

Temperature coefficient

0.04/K 

1) Maximum deviation, characteristic values determined at room temperature in accordance with ISO 10094.

Linearity refers to the ideal characteristic curve.

Tab. 11: Control characteristics