Technical data
Fig. 4: VPPE-3-1-1/8-2-... p1 = 0.4 MPa
Fig. 5: VPPE-3-1-1/8-6-... p1 = 0.8 MPa
Fig. 6: VPPE-3-1-1/8-10-... p1 = 1.1 MPa
Characteristic values
Design
Proportional-pressure regulator
Mounting position
As desired, preferably vertical (electronics upward).
Medium
[7:4:4]
Lubricated operation not possible
Pressure regulation range
[MPa]
0.002 … 0.2
0.006 … 0.6
0.01 … 1
Permissible input pressure
(Input pressure p1 min.
0.1 MPa above output pres-
sure p2)
[MPa]
0.3 … 0.4
0.6 … 0.8
0.6 … 1.1
Standard nominal flow rate
Total leakage when new
[l/h]
<
5
Ports
G 1/8
Nominal width
Pressurisation
[mm]
5
Exhaust port
[mm]
2.5
Degree of protection
IP65 in combination with connector socket according to
accessories
Permissible temperature range
Environment
[°C]
0 … +60
Storage
[°C]
–10 … +60
Medium
[°C]
+10 … +50
Electrical connection
Pin contact M12x1, 5-pin
Permitted supply voltage
24 V DC ± 10%
Setpoint variable
0 … 10 V/4 … 20 mA
Input resistance
10 kΩ (voltage) / 250 Ω (current)
Load actual value output
min. 2 kΩ (voltage)
max. 500 Ω (current)
Residual ripple
[%]
10
Vibration and shock
Vibration
Tested in accordance with DIN/IEC 68/EN 60068
Part 2-6,
Severity level 2
Characteristic values
Shock
Tested in accordance with DIN/IEC 68/EN 60068
Part 2-27,
Severity level 2
Power consumption
[W]
max. 4.2
Electromagnetic compatibility
–
EMC interference emission
and immunity to interference
See declaration of conformity
CE conformity for industrial installations fulfilled
Materials
Housing
Al
Cover
PA
Seals
NBR
Lubrication
silicone-free
Weight
[g]
390
Tab. 9: Characteristic values
Type of severity level (SL)
Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
SL1
SL2
SL1
SG2
SL1
SL2
2
…
8
2
…
8
–
–
±
3.5
±
3.5
8
…
27
8
…
27
10
10
–
–
27
…
58
27
…
60
–
–
±
0.15
±
0.35
58
…
160
60
…
160
20
50
–
–
160
…
200
160
…
200
10
10
–
–
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
SL1
SL2
SL1
SL2
SL1
SL2
±
150
±
300
11
11
5
5
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
±
150
6
1000
Tab. 10: Type of severity level (SL)
Control characteristics
1)
Linearity
1% Full Scale (FS) at 24 V DC and 25 °C
Hysteresis
Pressure regulation range
0.002 MPa … 0.2 MPa
1% Full Scale (FS)
Pressure regulation range
0.006 MPa … 0.6 MPa
0.5% Full Scale (FS)
Pressure regulation range
0.01 MPa … 1 MPa
0.5% Full Scale (FS)
Reproducibility
0.5% Full Scale (FS)
Total accuracy
Pressure regulation range
0.002 MPa … 0.2 MPa
1.5% Full Scale (FS)
Pressure regulation range
0.006 MPa … 0.6 MPa
1.25% Full Scale (FS)
Pressure regulation range
0.01 MPa … 1 MPa
1.25% Full Scale (FS)
Temperature coefficient
0.04/K
1) Maximum deviation, characteristic values determined at room temperature in accordance with ISO 10094.
Linearity refers to the ideal characteristic curve.
Tab. 11: Control characteristics