Assembly instructions (en) 

752 562 / 2010-10NH 

 

 

 

†‡

 

Vertical pressure shut-off plate 
VMPA1-HS 

Festo AG & Co. KG

 
Postfach 
D-73726 Esslingen 
++49/(0)711/347-0 
www.festo.com 

 

 

1.

 

Parts list 

 

15297d_1 

 

1

  Vertical pressure shut-off 

plate 

VMPA1-HS 

2

 Washer 

(2x) 

3

 Distance 

piece 

(2x) 

4

 Fibre-optic 

cable 

 

extension (1x) 

 

15297d_2 

 

Not included in scope of deliv-

ery: 

5

 Solenoid 

valve 

VMPA1-M1H-…-PI 

The vertical pressure shut-off plate 

1

 is intended to permit a valve change 

under operational and pilot pressure. The vertical pressure shut-off plate 

1

 

is located between the sub-base (B) and the valve 

5

 

 

Warning 

Beware of uncontrolled movements of components; 

they can result in injuries. 

 

Make sure that mounting or removal is performed in the pressureless 

state. 

 

 

Note 

The distance piece 

3

 includes an application of adhesive that

 

connects it 

to sub-base (B) when it is screwed in place (setting time 24 hours) and 

that

 

would be destroyed in case of removal. 

 

Please note that the vertical pressure shut-off plate 

1

 can no longer be 

removed after mounting. 

2.

 

Pre-assembly 

 

15297d_3 

 

 

Push the fibre-optic cable ex-

tension 

4

 onto the electron-

ics module (A). 

3.

 

Assembly 

 

15297d_4 

 

 

Check that the conical ring 

seal (D) is in the correct 

position  

(tapered side down). 

 

Position the vertical pressure 

shut-off plate 

1

 on the sub-

base (B). 

 

Place the washers 

2

 with 

the round side outward in 

the lateral slots. 

 

Fasten the vertical pressure 

shut-off plate 

1

 with both 

distance pieces 

3

.  

Observe the permitted tight-

ening torque. 

 

15297d_5 

 

 

Check that the conical ring 

seal (E) is in the correct posi-

tion  

(tapered side down). 

 

Position the valve 

5

 on the 

vertical pressure shut-off 

plate 

1

 

Tighten the screws (F). Ob-

serve the permitted tighten-

ing torque. 

 

Information 

The vertical pressure shut-off plate 

1

 supplies the valve 

5

 with internal 

pilot air. 

4.

 

Replacing the valve 

5

 under operating and pilot pressure 

 

 

15297d_6 

 

 

Block the operating pressure 

on the corresponding valve 

position by pressing the ac-

tuating element (G) down-

ward. 

 

Now lock

 

the pressure shut-

off plate 

1

 by turning the 

downward-pressed actuating 

element (G) 90° to the right. 

 

15297d_7 

 

After cutting off the operating 

pressure: 

 

Unscrew the screws (F). 

 

Replace the valve 

5

. Ob-

serve the permitted tighten-

ing torque 

 (

Section 3). 

Only after the valve change: 

 

Unlock the pressure shut-off 

plate 

1

 by turning the actu-

ating element (G) 90° to the 

left. 

 

Information 

After replacement of a valve in the actuated state, the new valve is actu-

ated again electrically, where appropriate. 

 

 

2

D

E

0.4 Nm 

_

 10% 

B

5

0.25 Nm 

_

 20% 

ß

 2 