Fault description

Cause

Remedy

Pressure remains constant des-
pite change to setpoint specific-
ation.

Supply cable breakage; the last
output pressure set is main-
tained but not regulated. Slow
pressure drop due to leakage.

Replace supply cable.

Setpoint value not reached.

Supply pressure p1 is too low.

Increase supply pressure p1.
Observe the max. permissible
operating pressure

è

 14 Technical Data.

Tab. 6

12

Dismounting

1. Switch off setpoint voltage.
2. Switch off operating voltage.
3. Switch off compressed air supply.
4. Remove electrical connecting cables.
5. Remove compressed air lines.
6. Dismantle the product.

13

Disposal

ENVIRONMENT!

Send the packaging and product for environmentally sound recycling in accord-
ance with the current regulations 

è

 www.festo.com/sp.

14

Technical Data

Property

Specification/value

Design

Proportional-pressure regulator

Mounting position

Any

Compressed air to ISO 8573-1:2010 [6:4:4]

Operating medium

Inert gases

Note on the operating medi-
um

Lubricated operation not possible

CE marking
(declaration of conformity

è

 www.festo.com/sp)

In accordance with EU-EMC Directive

1)

Degree of protection

IP65 (fully installed)

Climate class to EN 60721

3K3

Nominal operating voltage

[V DC]

24

Operating voltage range

[V DC]

19 … 29

Permissible residual ripple of
operating voltage

[%]

10

Maximum current consump-
tion

[mA]

80

Maximum signal line length

[m]

<

 30

Maximum permissible input pressure

VEAA-...-D2-...

[bar]

VEAA-...-D9-...

[bar]

VEAA-...-D11-...

[bar]

11

Pressure control range

VEAA-...-D2-...

[bar]

0.01 … 2

VEAA-...-D9-...

[bar]

0.03 … 6

VEAA-...-D11-...

[bar]

0.05 … 10

Accuracies

Absolute accuracy

[%]

£

 0.75 FS (full scale)

Repetition accuracy

[%]

± 0.4 FS (full scale)

Hysteresis

[%]

<

 0.25 FS (full scale)

Linearity error

[%]

<

 0.5 FS (full scale)

Analogue output

[%]

2 FS (full scale)

Permissible temperature range

Environment

[°C]

0 … +50

Medium

[°C]

+5 … +50 (non-condensing)

Storage

[°C]

–20 … +70

Setpoint value

Analogue input
(current variant)

[mA]

4 … 20

Analogue input
(voltage variant -V1-)

[V]

0 … 10

Analogue input (voltage
variant -V2-)

[V]

0 … 5

Input resistance setpoint value

at 4 … 20 mA

[

W

]

250

at 0 … 10 V

[k

W

]

10

at 0 … 5 V

[k

W

]

10

Property

Specification/value

Actual value

Analogue output
(current variant)

[mA]

4 … 20

Analogue output
(voltage variant -V1-)

[V]

0 … 10

Analogue output
(voltage -V2-)

[V]

1 … 5

Vibration resistance/shock resistance (as per IEC 60068)

Note

Explanation of the severity levels (SG)

è

 Tab. 8 Features of severity level (SL)

Vibration (part 2 - 6)

Mounting via through-holes

SG2

Mounting on H-rail, mounting
plate, manifold rail

SG1

Shock (part 2 – 27)

Mounting via through-holes

SG2

Mounting on H-rail, mounting
plate, manifold rail

SG1

Continuous shock (part 2 – 27)

Mounting via through-holes

SG1

Mounting on H-rail, mounting
plate, manifold rail

SG1

Materials

Housing

PA, PAMX

Screws

Heat-treated steel
Galvanised steel

Seals

NBR

Adapter plate

Wrought aluminium alloy

Weight

Weight

[g]

Approx. 55

Weight

[g]

Approx. 55

1) The component is intended for industrial use. Outside industrial environments, e.g. in commercial and res-

idential/mixed-use areas, it may be necessary to take measures to suppress radio interference.

Tab. 7 General Technical Data

Features of severity level (SL)

Vibration load

Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SL1

SL2

SL1

SL2

SL1

SL2

2 … 8

2 … 8

±3.5

±3.5

8 … 27

8 … 27

10

10

27 … 58

27 … 60

±0.15

±0.35

58 … 160

60 … 160

20

50

160 … 200

160 … 200

10

10

Shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SL1

SL2

SL1

SL2

SL1

SL2

±150

±300

11

11

5

5

Continuous shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

±150

6

1000

Tab. 8 Features of severity level (SL)

Отзывы: