Pin assignment of control plug  (AMPLIFIER, X30)

1

2

3

4

5

6

7

8

+ PULSE
+ DIRECT. (direction)
+ ENABLE 
not connected
+  F/H STEP (full/half step)
-   F/H STEP (full/half step)
not connected
+ READY

9

0

!

"

#

$

%

- PULSE
- DIRECT. (direction)
- ENABLE
not connected
not connected
not connected
- READY

The designation of the pins refers to the power controllers from the
Festo drive packages.

Use the appropriate cable, type KSMX-SM5-... , from Festo for
connecting the power controller to the control plug.

If you are using a ready-made cable, connect the cable
screening on both sides to the plug housing.

8

3
2
1

%

9

.

.

.

.

.

.

E

n

g

lis

h

SPC200-SMX-1

16

9903NH

Содержание SPC200-SMX-1

Страница 1: ...Kurzbeschreibung Schrittmotor Indexer Baugruppe Typ SPC200 SMX 1 Brief description Stepping motor indexer module type SPC200 SMX 1 9903NH 388 648...

Страница 2: ...Deutsch 3 English 11 Festo AG Co D 73726 Esslingen 1999 SPC200 SMX 1 9903NH 2...

Страница 3: ...ektrischen Li nearachse Typ DGE L VORSICHT Beachten Sie unbedingt die dort aufgef hrten Sicherheitstechnischen Hinweise den bestimmungsgem en Gebrauch der jeweiligen Baugruppen und Module Weiterf hren...

Страница 4: ...cht Es k nnen abh ngig von den zur Verf gung stehenden Steck pl tzen bis zu 3 Schrittmotor Indexer Baugruppen in einen Baugruppentr ger installiert werden HINWEIS Montieren Sie die Schrittmotor Indexe...

Страница 5: ...verkanten und keine Bauteile auf der Leiterplatte besch digt werden 3 Achten Sie darauf da die Stecker der Messerleisten richtig aufeinander liegen Schieben Sie die Baugruppe dann mit leichtem Druck...

Страница 6: ...enn sie die sichere Trennung im Sinne der EN 60950 VDE 0805 gew hrleisten HINWEIS Verbinden Sie den Erdungsanschlu des Baugruppentr gers niederohmig kurze Leitung mit gro em Querschnitt mit dem Erdpot...

Страница 7: ...Die Genauigkeit des Referenzpunkts h ngt vom verwendeten Referenzschalter ab Verwenden Sie einen Referenzschalter dessen Umschaltpunkt innerhalb einer Schrittaufl sung liegt Beschaltung Steuerstecker...

Страница 8: ...LE Tor Enable n c nicht verbunden n c nicht verbunden n c nicht verbunden READY Bereitschaft Die Bezeichnung der Anschl sse bezieht sich auf die Leistungs ansteuerungen aus den Festo Antriebspaketen V...

Страница 9: ...el Motor 7 8 9 0 Elektromechanischer Linearantrieb Sensorkabel SPC200 Schaltschrank Steuerkabel 4 Technische Daten Typ SPC200 SMX 1 Temperaturbereich Betrieb Lagerung Transport 5 o C 50 o C 20 o C 70...

Страница 10: ...aiskontakt RS 485 Gegentaktsteuerung 80 Hz bis 40 kHz max 500 kHz sec 0 0 bis 9999 999 mm 0 01 bis 9999 99 Schritte mm Elektromagnetische Vertr glichkeit St raussendung St rfestigkeit gepr ft nach EN...

Страница 11: ...electrical linear axis type DGE L CAUTION Pay strict attention to the following instructions shown therein safety guidelines specifications for the use of the individual modules and components More in...

Страница 12: ...0 Depending on the number of locations available up to 3 stepping motor indexer modules can be fitted into a rack PLEASE NOTE If you are using an operating panel fit the stepping motor in dexer module...

Страница 13: ...nd make sure that none of the components on the printed circuit board are damaged 3 Make sure that the pins on the connectors are correctly aligned Then with a light pressure of the fingers push the m...

Страница 14: ...ee reliable isolation in accordance with EN 60950 VDE 0805 PLEASE NOTE Connect the earthing connection of the rack with low impe dance to the earth potential short cable with large cross sectional are...

Страница 15: ...contact The accurcy of the reference point depends on the reference switch used Use a reference switch with a switching point within a step resolution Circuit diagram of control plug AMPLIFIER X30 DC...

Страница 16: ...tion ENABLE not connected not connected not connected READY The designation of the pins refers to the power controllers from the Festo drive packages Use the appropriate cable type KSMX SM5 from Festo...

Страница 17: ...e Motor 7 8 9 0 Electromechanical linear drive Sensor cable SPC200 Control cabinet Control cable 4 Technical specifications Type SPC200 SMX 1 Temperature range operation storage transport 5 o C 50 o C...

Страница 18: ...LS via relay contact RS 485 push pull control 80 Hz to 40 kHz max 500 kHz sec 0 0 bis 9999 999 mm 0 01 bis 9999 99 steps mm Electromagnetic compatibility interference emitted resistance to interferenc...