Bedienungsleitung/Operating instructions
SKDA-...-AB
20 www.Festo.com
Änderungen vorbehalten – 2016/10
6
Mechanical installation conditions of sensors
6.1
Precautions to take during assembly
Force measuring equipment is extremely sensitive and must be
handled carefully.
Attention must be paid to the installation position and therefore the
load direction when the sensors are being installed.
Torsional moments, off-centre loads and lateral loads cause
measuring errors and can permanently damage the sensors.
Care must therefore be taken to keep the sensor free of lateral
loads and torsion during assembly (e.g. when tightening the lock
nuts).
Overloading must be prevented at all times.
The output signal (4...20mA) is noted on the technical
dokumantaion (data sheet/operation instructions). The connection
assignments are also noted in the section entitled “Electrical
connection”. The polarity must be correct at all times.
On the name plate, you can find follow informations:
Abb. 2 Name plate
1
CE-Mark
2
title
3
part number
4
5
serial number
6
company logo