OVEM
Festo – OVEM – 1407c English
79
Display
Mode
Description
Symbol
Display
TEA
CH
EDIT
SHOW
Description
RU
N
Symbol
[Option]
Air-saving function active
X X X
[Lock]
Security code active
(blocking of unauthorised parameterisation)
X
X
Graphic display of the current measured value
related to the maximum measured value of the
measuring range. The left-hand segment row
shows the measured value of In A1, the right-
hand segment row shows the status of In and
the solenoid valves.
Significance in other modes
è
X
Special menu (SPEC) is active
1)
X
In A1
(digital
display)
Pressure measurement value controls switching
output Out B
X X
di1
(digital
display)
Diagnostic message channel 1 controls switch
ing output Out B
X X
di2
(digital
display)
Diagnostic message channel 2 controls switch
ing output Out B
X X
Er X
(digital
display)
Error message, error number
è
X
ON/OFF
Diagnostic channel set/not set
– / no ejector pulse
Lock active/ not active
Air-saving function active/ not active
X
FORC
(digital
display)
Additional function of the manual override via
operating buttons
X
1)
The segment bars also show special symbols
è
Tab. 9
Symbols on the display
Содержание OVEM
Страница 52: ...OVEM 52 Festo OVEM 1407c Deutsch Fig 23 SHOW Modus ...
Страница 53: ...OVEM Festo OVEM 1407c Deutsch 53 Fig 24 EDIT Modus ...
Страница 54: ...OVEM 54 Festo OVEM 1407c Deutsch Fig 25 TEACH Modus ...
Страница 106: ...OVEM 106 Festo OVEM 1407c English Fig 23 SHOW mode ...
Страница 107: ...OVEM Festo OVEM 1407c English 107 Fig 24 EDIT mode ...
Страница 108: ...OVEM 108 Festo OVEM 1407c English Fig 25 TEACH mode ...