Festo — MSE6-E2M — 2022-08d
Parameterisation
61
9.4
Modifiable module parameters
Module parameter: Monitor
Function number
4828 + m * 64 + 0
m = module number 1
Description
The monitoring of single errors can be independently activated, deactivated or
suppressed for the energy efficiency module.
Activation of the monitoring function causes the following:
–
The error is sent to the bus node.
–
The error is displayed via the module error LED.
Bit
Meaning
0
Monitoring SCS, short circuit/overload sensor supply
1
Monitoring SCO, short circuit/overload outputs
2
Undervoltage monitoring U
Out/A
6
Monitoring of limit values
7
Monitoring of parameters
Values
0 = not active
1 = active, default
Comment
Monitoring of parameters:
Some parameters are checked for non-permitted values during parameterisa-
tion, e.g.
–
Limit value monitoring startup
–
Units of measure
–
Limit values
Tab. 45: Monitor module parameter