background image

1.

 

Parts lists 

1.a.

 

Mesh filter cartridge MS6-SP 

9054d_10 

1

    Mesh filter cartridge 

MS6-SP 

2

    Screws 

M2x16 

Not included in delivery: 

3

    Flow sensor 

MS6-SFE-F5-… 

1.b.

 

Stabilizing attachment MS6-ES 

9054d_11 

 

2

    Screws 

M2x16 

4

    Stabilizing attachment 

MS6-ES 

Not included in delivery: 

5

    Flow sensor 

MS6-SFE-F5-AGD-… 

6

    Module connector 

MS6-MV 

2.

 

For removing mesh filter cartridge 

9054d_2 

 

 

Tighten screws 

2

 in the 

thread intended for this in 
the mesh filter cartridge 

1

9054d_3 

 

 

Pull the mesh filter car-
tridge 

1

 by the screws 

2

 

out of the flow sensor 

3

3.

 

For fitting the mesh filter cartridge 

9054d_4 

 

 

Make sure the sealing 
rings are correctly seated 
in the mesh filter cartridge 

1

 

Press the mesh filter 
cartridge 

1

 by the edge 

into the flow sensor 

3

 

Make sure that the mesh 
filter cartridge 

1

 and its 

seals are not damaged. 

4.

 

For removing the stabilizing attachment 

9054d_6 

 

 

Remove the module con-
nector 

6

 from the flow 

sensor 

5

9054d_7 

 

 

Pull off the stabilizing 
attachment 

4

5.

 

For fitting the stabilizing attachment 

9054d_8 

 

 

Make sure the sealing 
rings are seated correctly 
on the stabilizing attach-
ment 

4

 

Make sure the protection 
against rotation is posi-
tioned correctly on the 
stabilizing attachment 

4

 

Press the stabilizing at-
tachment 

4

 into the flow 

sensor 

5

9054d_9 

 

 

Fasten the stabilizing 
attachment 

4

 with the 

module connector 

6

Assembly instructions (en) 
696 874 / 2006-02NH 

†‡

Mesh filter cartridge / Stabilizing at-

tachment 
MS6-SP / MS6-ES  

Festo SE

 & Co. KG

Postfach 
73726 Esslingen 
++49/(0)711/347-0 
www.festo.com 

6

5

5

5

6

5