1.
Parts lists
1.a.
Mesh filter cartridge MS6-SP
9054d_10
1
Mesh filter cartridge
MS6-SP
2
Screws
M2x16
Not included in delivery:
3
Flow sensor
MS6-SFE-F5-…
1.b.
Stabilizing attachment MS6-ES
9054d_11
2
Screws
M2x16
4
Stabilizing attachment
MS6-ES
Not included in delivery:
5
Flow sensor
MS6-SFE-F5-AGD-…
6
Module connector
MS6-MV
2.
For removing mesh filter cartridge
9054d_2
•
Tighten screws
2
in the
thread intended for this in
the mesh filter cartridge
1
.
9054d_3
•
Pull the mesh filter car-
tridge
1
by the screws
2
out of the flow sensor
3
.
3.
For fitting the mesh filter cartridge
9054d_4
•
Make sure the sealing
rings are correctly seated
in the mesh filter cartridge
1
.
•
Press the mesh filter
cartridge
1
by the edge
into the flow sensor
3
.
•
Make sure that the mesh
filter cartridge
1
and its
seals are not damaged.
4.
For removing the stabilizing attachment
9054d_6
•
Remove the module con-
nector
6
from the flow
sensor
5
.
9054d_7
•
Pull off the stabilizing
attachment
4
.
5.
For fitting the stabilizing attachment
9054d_8
•
Make sure the sealing
rings are seated correctly
on the stabilizing attach-
ment
4
.
•
Make sure the protection
against rotation is posi-
tioned correctly on the
stabilizing attachment
4
.
•
Press the stabilizing at-
tachment
4
into the flow
sensor
5
.
9054d_9
•
Fasten the stabilizing
attachment
4
with the
module connector
6
.
Assembly instructions (en)
696 874 / 2006-02NH
†‡
Mesh filter cartridge / Stabilizing at-
tachment
MS6-SP / MS6-ES
Festo SE
& Co. KG
Postfach
73726 Esslingen
++49/(0)711/347-0
www.festo.com
2
1
2
1
3
1
2
3
1
3
4
6
6
5
4
5
4
5
4
6
6
5
4
2