Festo MPAL-VI Скачать руководство пользователя страница 2

6

Terminal strip

6.1 Specification of the cables

Specification of the cables

Conductor  cross-section

0.08 … 0.5 mm

2

 or AWG 28 … 20

Stripping

5 … 6 mm

Permitted copper
conductors

Single wire, multi-wire, fine wire, also with tin-plated single conductors

Fine wire, strands compressed

Fine wire with wire end sleeves (crimped on gas-tight) 

1)

Fine wire with pin terminal (crimped on gas-tight) 

1)

1)

If necessary, use the next smaller conductor cross section.

Fig. 3

6.2 Mounting/dismounting of the cables

Note

 To ensure a reliable contact, only connect one conductor per terminal.
 Only insert cables into the terminal opening.

Pushing a screwdriver into the opening may damage the terminal.

1

2

3

4

5

1

Screwdriver

2

Cable ends

3

Terminal strip

4

Terminal opening

5

Actuating lever

Fig. 4

1. Press the screwdriver 

1

 against the white actuating lever 

5

.

è

The terminal of the terminal strip 

3

 opens.

2. Insert or pull out the ends of the cable 

2

 through the opening 

4

.

3. Put down the screwdriver 

1

.

è

Actuating lever 

is slack.

è

The terminal of the terminal strip is closed and the cable clamped.

7

Earth valve terminal

Note

Observe the following points to avoid malfunctions from electromagnetic inter­
ference:
 Use a large-cross-section earth conductor that is as short as possible.

The earth conductor should ideally be a braided conductor, alternatively a
cable with a cross section of at least 2.5 mm², preferably 4 mm², and a maxim­
um length of 20 cm. A different cable may be required depending on the
installation situation.

 Connect the earth terminal with low resistance and low impedance to the

earth potential.

1

2

1

Earth terminal on the left end plate

2

Earth terminal on the right end plate
(grounding screw premounted)

Fig. 5

 Connect one of the earth terminals (

è

 Fig. 5) to the earth potential.

8

Address assignment of the valves

Addresses are allocated in ascending order without gaps, from left to right. Depen­
ding on the integrated electrical interlinking module, a valve position occupies the
following number of addresses:

Electrical interlinking module

Number of
valve positions

Number of

occupied

addresses per

valve position

Type

Housing
colour

Individual electrical interlinking module

VMPAL-EVAP-…-1

Grey

1

1

VMPAL-EVAP-…-2

Black

1

2

4-fold electrical interlinking module

VMPAL-EVAP-…-1-4

Grey

4

1

VMPAL-EVAP-…-2-4

Black

4

2

Electrical interlinking module of the power supply module

VMPAL-EVAP-20-SP

Black

0

0 (signals are

passed through)

Fig. 6

If one valve occupies both addresses of a valve position:
– Solenoid coil 14 occupies the less significant address.
– Solenoid coil 12 occupies the higher-value address.

Address assignment does not depend on it is equipped with blanking
plates or valve plates.
Additional information 

è

 Description MPAL-VI

9

Technical data

General information

Dimensions

è

 Description MPAL-VI

Ambient temperature (in operation)

–5 … +50

 °

C

Storage temperature

–20 … +40

 °

C

Degree of protection in accordance with
EN 60529 for completely mounted valve
terminal

– IP40 (open cover)
– IP67 (closed cover)

Protection against electric shock 
(protection against direct and indirect con­
tact in accordance with IEC/EN 60204-1)

Through the use of PELV circuits
(Protected Extra-Low Voltage)

CE marking (see declaration  of  conformity)

è

 www.festo.com/sp

In accordance with EU EMC Directive 

1) 2)

Materials

è

 Description MPAL-VI

1)

The product is intended for use in industrial environments. If the product is used in a low-voltage net­
work that also supplies residential areas, actions against interference may be required.

2)

The maximum permitted signal cable length for the valve terminal with multi-pin plug connection is 30 m.

Fig. 7

Pneumatics

Number of valve  positions

Max. 32, 
dependent on the variant of the multi-pin plug connection 

è

 Chap. 5

Medium

Compressed air in accordance with ISO 8573-1:2010 [7:4:4] 
lubricated or unlubricated (oil: VG32)

Notes on the operating/
pilot medium

Lubricated operation possible (in which case lubricated operation
will always be required)

Operating pressure

With int. pilot air

3 … 8 bar

With ext. pilot air

Dependent on the valve sub-base types used 

è

 Description MPAL-VI

Fig. 8

Electrical data

Power supply

Nominal voltage

24 V DC (±25 %)

Current consumption
(per coil, with LED) at 24 V

MPA1

MPA14

MPA20

Nominal pick-up
current

 50 mA

 50 mA

 110 mA

Pick-up duration

Approx. 20 ms

Nominal current with
current reduction

 10 mA

 10 mA

 23 mA

Fig. 9