7
Conversion
56
Festo – MPAC-VI-EN – 2017-12a – English
7.6
Conversion of the outlet orientation for the electrical connection
Dependent on your order, the electrical connection is either on the front side (valve side) or the reverse
side (connection side). You can subsequently change the position of the electrical connection by repla
Note
Valve terminals with a maximum of 2 manifold sub-bases:
To replace the left end plate, you will need 5 new threaded rods,
since the short threaded rods in the left end plate of your valve ter
minal cannot be removed with conventional tools.
End plate, left
Outlet
orientation
Connection type
Type code
Front side
(top)
Multi-pin plug
connection, Sub-D,
25 pins
VMPAC-EPL-MP-SD25-O
Multi-pin plug
connection, Sub-D,
44 pins
VMPAC-EPL-MP-SD44-O
Connection
IO-Link, Sub-D,
9 pins
VMPAC-EPL-IP-O
Reverse side
(underneath)
Multi-pin plug
connection, Sub-D,
25 pins
VMPAC-EPL-MP-SD25
Multi-pin plug
connection, Sub-D,
44 pins
VMPAC-EPL-MP-SD44
Connection
IO-Link,
Sub-D
9 pins
VMPAC-EPL-IP
Tab. 7.3
Variants of the left end plate
Dismounting
1. Loosen the electrical and pneumatic connections and then
remove the valve terminal from its mounting surface (
è
2. Place the valve terminal on a flat working surface.