The assignment of the outputs to the relevant
valve location is shown in the diagram below.

Example:
Addressing and activating the valves

0.01

0.03

0.05

0.07

0.08

0.11

0.13

0.15

1.01

1.03

0.00

0.02

0.04

0.06

0.09

0.10

0.12

0.14

1.00

1.02

Valve locations

Outputs of the

valve locations

Outputs of the valve

locations

No.

0

No.

1

No.

2

No.

3

No.

4

No.

5

No.

6

No.

7

No.

8

No.

9

Fig. 5/2:  Outputs of the valve locations

Valve
location
no.

Valve type

Output

Bit
con-
tents

Remarks

2

single solenoid

O0.04
O0.05

1

X

Valve solenoid coil active
Output not evaluated

9

double solenoid

O1.02
O1.03

0
1

Upper valve solenoid coil not active
Lower valve solenoid coil valve

Fig. 5/3: Example – Addressing and activating valves

VIFB8 – 02               5. Commissioning

9706

5-7

Содержание IIFB-02- Series

Страница 1: ...9706 151763 GB Valve Terminal Valve Sensor Terminal with Field Bus Connection VIFB8 IIFB8 02 Manual Fieldbus protocol Allen Bradley Remote I O link...

Страница 2: ...of germany 1997 The copying distribution and utilization of this document as well as the communication of its contents to others without expressed authoriza tion is prohibited Offenders will be held...

Страница 3: ...B8 02 GB PLC 2 is a registered trademark of Allen Bradley Company Inc PLC 3 is a registered trademark of Allen Bradley Company Inc PLC 5 is a trademark of Allen Bradley Company Inc SLC 500 is a tradem...

Страница 4: ...L DESCRIPTION Chapter 4 INSTALLATION 4 1 Fitting the valve terminal valve sensor terminal 4 1 4 2 Installing the pneumatic components 4 5 4 3 Installing the electronic components 4 19 Chapter 5 COMMIS...

Страница 5: ...VIFB8 02 IV 9706...

Страница 6: ...1 IMPORTANT USER INSTRUCTIONS VIFB8 02 1 Important user instructions 9706 1 1...

Страница 7: ...Contents IMPORTANT USER INSTRUCTIONS 1 3 VIFB8 02 1 Important user instructions 1 2 9706...

Страница 8: ...between the following in structions WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation...

Страница 9: ...ontroller from Valve size No of valve locations Valve terminal type 02 VIFB 02 Allen Bradley 1 8 or 1 4 4 or 6 or 8 or 10 or 12 or 14 or 16 Valve sensor terrminal type 02 IIFB 02 Fig 1 1 Designs of va...

Страница 10: ...2 SYSTEM STRUCTURE VIFB8 02 2 System structure 9706 2 1...

Страница 11: ...Contents SYSTEM STRUCTURE 2 3 Valve terminal 2 3 Valve sensor terminal 2 4 Valve terminal valve sensor terminal in the control system 2 5 VIFB8 02 2 System structure 2 2 9706...

Страница 12: ...omation process The valve terminal with 1771 RIO offers the fol lowing advantages decentralized preprocessing relieves the pro grammable controller less wiring due to 2 wire twisted pair cables clarit...

Страница 13: ...pulse valves etc are fitted onto a connection block and have already been tested two sensors per valve can be connected on site Valve sensor terminals with from 4 14 valves are available for the auto...

Страница 14: ...al with RIO links connection as part of a A B control system PLEASE NOTE The valve terminals and valve sensor termi nals are not compatible with the Data Highway Data Highway PlusTM DIO bus system or...

Страница 15: ...ctuator IIFB8 02 VIFB8 02 Power unit AC 24 V Allen Bradley 1771 I O chassis RIO RIO A B PLC 3 Fig 2 4 System structure of Allen Bradley RIO link with valve terminal valve sensor terminal VIFB8 02 2 Sy...

Страница 16: ...s the actuators which are connected The valve terminal is supplied with current via an ex ternal power unit AC 115V 230 V DC 24V The valve sensor terminal as a decentralized input output device functi...

Страница 17: ...VIFB8 02 2 System structure 2 8 9706...

Страница 18: ...3 TECHNICAL DESCRIPTION VIFB8 02 3 Technical description 9706 3 1...

Страница 19: ...Valve sensor terminal 3 5 Function 3 8 Explanation on function summary 3 9 Technical specifications 3 10 General 3 10 Electronic components 3 11 RIO link 3 13 Pneumatic components 3 14 Connection blo...

Страница 20: ...ve terminal base unit consisting of Valve coupling unit upper part Connection block lower part 3 Valve locations for Solenoid pulse valves or Solenoid mid position valves Solenoid valves or Relay boar...

Страница 21: ...1 Valve terminal inscription field 2 Red LED Power 3 Green LED Bus 4 Operating voltage connection 5 RIO interface 6 Type plate 7 Valve location inscription field per valve solenoid coil 8 Yellow LED...

Страница 22: ...Figure Components 1 RIO node 2 Valve sensor terminal base unit consisting of Valve sensor coupling unit upper part Connection block lower part 3 Valve locations for Solenoid pulse valves or Solenoid m...

Страница 23: ...voltage connection 7 RIO interface 8 Type plate 9 Connections for inputs e g sensors 10 Inscription field inputs additional outputs per connection 11 Yellow or green LED per additional input output 12...

Страница 24: ...he RIO node and contains the following specifica tions Type designation of base unit here valve sensor terminal Part number Max operating pressure in bar and psi Permitted operating voltage IIFG 02 1...

Страница 25: ...l valve sensor terminal as slave The scanner transmits a message to the valve terminal valve sensor terminal The valve termi nal sends a reply message to the RIO scanner Programmable controller RIO sc...

Страница 26: ...smits the pulses to the valves The valve sensor coupling unit of the valve sensor terminal contains the operating voltage connection and a decoder This decodes the signals from the RIO node and transm...

Страница 27: ...tions of the 1 8 design are given in round brackets 259 5x 288 x 141 mm 235 5x 275 4 x 139 5 mm 325 5x 288 x 141 mm 289 5x 275 4 x 139 5 mm 391 5x 288 x 141 mm 343 5x 275 4 x 139 5 mm 457 5x 288 x 141...

Страница 28: ...t capacity of inputs P W 0 2 A I Inputs 24 V Power failure holdup time min 20 ms Operating voltage outputs Pin 2 Operating voltage connection Rated value protected against incorrect polarity Tolerance...

Страница 29: ...verload Trigger current Response time short circuit max 0 5 A Bulbs max 10 W because of PTC resistor characteristics max 1 A max 1 s Inputs valve sensor terminal Logic level ON OFF Voltage range Curre...

Страница 30: ...Baud 230 4 kBaud Cable type Belden 9463 shielded twisted pair Cable length 3 3 km at 57 6 kBaud 1 6 km at 115 2 kBaud 0 8 km at 230 4 kBaud Terminators refer to A B publications Cable installation Plu...

Страница 31: ...ool valve 40 m 40 m Pressure Operating pressure range Rated pressure Highest pressure at 1 2 bar 10 bar 29 psi 145 psi 6 bar 87 psi 10 bar 145 psi Fastening Type Mounting 4 through holes From the fron...

Страница 32: ...Please unfold for page 3 16 Please unfold for page 3 16 VIFB8 02 3 Technical description 9706 3 15...

Страница 33: ...VI 1 8 M4x50 MVH 5 1 4 L B VI 1 4 Spool valve bilaterally operated 5 2 way Soft piston in sleeve with pressure relief slots Outlet slots are overrun without M4x55 MVH 5 1 8 L B VI 1 8 M4x50 MVH 5 1 4...

Страница 34: ...Q 1100 CV 1 12 19 ms 41 ms 1 8 2 10 bar G1 8 5 mm Q 750 CV 0 76 17 ms 36 ms 1 4 3 10 bar G1 4 10 mm Q 1600 CV 1 63 33 ms 40 ms 1 8 G1 8 8 mm Q 1000 CV 1 02 30 ms 100 ms 1 4 0 9 10 bar 3 10 bar 3 10 ba...

Страница 35: ...Please unfold for page 3 17 Please unfold for page 3 17 VIFB8 02 3 Technical description 3 18 9706...

Страница 36: ...4 1 FITTING THE VALVE TERMINAL VALVE SENSOR TERMINAL VIFB8 02 4 Installation 9706 4 1...

Страница 37: ...Contents FITTING THE VALVE TERMINAL VALVE SENSOR TERMINAL 4 3 VIFB8 02 4 Installation 4 2 9706...

Страница 38: ...or right of the connection block for fitting the hoses and if necessary the silencers There are 4 through holes on the right and left hand edges of the connection block for fastening the valve termin...

Страница 39: ...olts M6x60 The bolts should be tightened in diagonally opposite sequence Valve terminal valve sensor terminal Distance between holes mm L1 L2 VIFB IIFB 02 1 4 1 8 4 VIFB IIFB 02 1 4 1 8 6 VIFB IIFB 02...

Страница 40: ...4 2 INSTALLING THE PNEUMATIC COMPONENTS VIFB8 02 4 Installation 9706 4 5...

Страница 41: ...ng the connection block 4 10 Connecting the valves 4 11 Solenoid valve 5 2 way 4 12 Solenoid pulse valve 5 2 way and Solenoid mid position valve 5 3 way 4 13 Checking the valve functions 4 14 Manual o...

Страница 42: ...e switched off the operating voltage for electronic components and or inputs the operating voltage supply the compressed air You thereby avoid uncontrolled movement of loosened hoses undesired movemen...

Страница 43: ...hose as far as it will go into or over the screw connection 2 Pull the locking ring over the hose connec tion or tighten the locking screw 3 For reasons of clarity the hoses should be grouped together...

Страница 44: ...the following cases When the valve terminal valve sensor termi nal has more than 10 valves rated supply pressure 6 bar With large volume actuators The connections should be made in accordance with th...

Страница 45: ...Common lines Connection code ISO 5599 Size of connection ISO 228 Connection Compressed air 1 G 1 2 G3 8 Screw connector Exhaust 5 3 3 5 G 1 2 G3 8 Screw connector with common exhaust or scilencer Pilo...

Страница 46: ...uld be of aluminium Proceed as follows Remove the lupolen plugs and fit the screw con nectors with the appropriate seals as indicated in the following tables Fig 4 5 Pin assignment of solenoid valve F...

Страница 47: ...VI MVH 5 1 8 L S B VI Line Connection code ISO 5599 Size ISO 228 Connection Work air 2 4 G 1 4 G1 8 Screw connector or multiple distributor Auxiliary pilot air 14 G 1 8 G1 8 Only with S valves Pneuma...

Страница 48: ...nnection Work air 2 4 G 1 4 G1 8 Screw connec tor or multiple distributor Auxiliary pilot air 12 14 G 1 8 G1 8 only S valve Work air Auxiliary pilot air only S valve 14 4 2 Auxiliary pilot air only S...

Страница 49: ...the actuators the installed EMERGENCY STOP circuit has no effect The manual override is mainly used when com missioning the pneumatic components to test the function of the valve or valve cylinder co...

Страница 50: ...set Basic setting as at factory After operation the manual override is reset by spring force Manual override with stop Conversion of manual override necessary see Appendix A Manual override Two versio...

Страница 51: ...rating the manual override Reaction of valve or of processor Press the plunger of manual override as far as it will go The valve or the processor switches Hold plunger of manual override pressed down...

Страница 52: ...rt screwdriver in groove of plunger Press plunger as far as it will go and turn it to the right The valve or processor switches Remove screwdriver remains switched Insert screwdriver in the groove of...

Страница 53: ...Valve or pneumatic system does not react as expected does not react Switch position Switch position Check the hose lines or check auxiliary pilot air Check operating pressure or check auxiliary pilot...

Страница 54: ...4 3 INSTALLING THE ELECTRONIC COMPONENTS VIFB8 02 4 Installation 9706 4 19...

Страница 55: ...nal valve sensor terminal 4 29 Connetcting the cables to the plugs sockets 4 29 24V operating voltage connection 4 31 Applying the 24V operating voltage 4 34 RIO interface 4 37 RIO cable 4 38 Connecti...

Страница 56: ...ched off the operating voltage for electronic components and or inputs the operating voltage for outputs the compressed air supply You thereby avoid uncontrolled movement of loosened hoses undesired m...

Страница 57: ...this chapter The following table summarizes the procedure 1 4 1 Switching off Operating voltage Compressed air supply 2 Configuring the valve terminal valve sensor terminal Opening the RIO node Addres...

Страница 58: ...ing connection and display elements are situated on the cover of the RIO node Opening Unscrew the 4 Philips screws in the cover and remove the cover Closing Replace the cover on the RIO node and tight...

Страница 59: ...tains the red LED board 2 contains a green LED and a switch for setting the address and baud rate 1 2 DIL switch baud rate Green LED Address selector switch RIO connection Board 2 Screening Board 1 Re...

Страница 60: ...device Only a clear specification of the RIO addresses guarantees the faultless NOMINAL ACTUAL comparison in the configuration Recommendation We recommend that the RIO addresses be as signed in ascen...

Страница 61: ...voltage 2 Assign a non reserved RIO address to the valve terminal valve sensor terminal 3 With a screwdriver set the arrow of the appro priate address selector switch to the tens and or units figure o...

Страница 62: ...0 1 3 4 6 5 2 7 8 9 0 1 3 4 6 5 2 7 8 9 0 1 3 4 6 5 2 7 8 9 0 1 3 4 Example 1 Example 2 RIO address set 05 RIO address set 38 UNITS TENS UNITS TENS Fig 4 16 Example of RIO addresses set VIFB8 02 4 Ins...

Страница 63: ...the setting on the programmable control ler master The following A B specific functions are not implemented Last Chassis cf p 5 14 Hold Last State Processor Restart Lockout DIL switch Baud rate 57 6 k...

Страница 64: ...llows see following diagram Power supply socket Insert the power supply socket into the operating voltage plug on the valve termi nal valve sensor terminal Unscrew the con nection part of the socket N...

Страница 65: ...8 0 mm for sensor plug 4 0 mm 6 0mm for RIO cable socket PG 9 8 0 mm 9 5 mm PG13 5 12 0 mm 13 5 mm 3 Remove the insulation from 5 mm of the end of the cables 4 If necessary fit the strands with cable...

Страница 66: ...f of the plug socket to prevent the cable connection from becoming loose 24 V operating voltage connection The connection for the operating voltage is on the left hand edge of the base unit of the val...

Страница 67: ...st be earthed in order to ensure function e g EMC The following components of the valve termi nal valve sensor terminal are supplied separately with 24V DC via this connection The operating voltage fo...

Страница 68: ...is operating Please see that the operating voltage of the out puts is within the permitted tolerances even dur ing full operation PLEASE NOTE Always connect the earth potential to pin 4 of the operat...

Страница 69: ...ket see Chapter 3 Techni cal specifications Please see also the example of connection in Fig 4 21 The operating voltage supply to the electronic components and for inputs is fused at the valve termina...

Страница 70: ...PLEASE NOTE Check your EMERGENCY STOP circuritry to see which measures are required in order to place your machine system in a safe state in the event of an EMERGENCY STOP e g switching off the power...

Страница 71: ...sumption of electronic components field bus node and inputs sensors max 4 A Current consumption of outputs pin 2 24 V 10 Number of valve coils simultaneously supplied with current _____ x0 120 A Numbe...

Страница 72: ...he con tinuing RIO cable The signal cables of the two plugs are connected together This enables the RIO to be connected to further RIO participants Recommendation On all valve terminal valve sensor te...

Страница 73: ...the RIO interface CAUTION Please observe the polarity when the RIO cables are connected The following diagram shows the pin assignment of the RIO interface The RIO cables should be connected to the se...

Страница 74: ...km PLC 2 all 16 150 57 6 3 3 28 82 57 6 3 3 28 82 115 2 1 6 PLC 3 1775 S4A 1775 S5 16 150 57 6 3 3 32 82 57 6 3 3 32 82 115 2 1 6 PLC 5 built in or 5150 RS for PLC 5 250 16 150 57 6 3 3 32 82 57 6 3...

Страница 75: ...refore no longer guaranteed For this reason a protective cap must be fitted to the non used bus plug A terminating resistor is required at both ends of the RIO cable If the valve terminal valve sensor...

Страница 76: ...commend that the wires of the resistor and those of the incoming RIO cable be crimped together in common cable end sleeves 2 Fit the sensor RIO cable socket onto one of the plugs on the RIO node 3 Co...

Страница 77: ...unilaterally operated valves the output with the even bit number is used The other output cannot be used for other purposes Additional outputs There are two additional outputs O0 00 and O0 01 on the...

Страница 78: ...assignment of additional outputs Fig 4 28 Pin assignment of sockets with additional outputs free 3 0 V O 0 01 free free 2 1 4 3 free 0 V O 0 00 O0 01 O0 00 2 1 4 Socket VIFB8 02 4 Installation 9706 4...

Страница 79: ...he valve sen sor terminal There are two additional inputs ab ove the RIO node The inputs have positive logic PNP inputs PNP inputs Common fuse 4 A slow blowing for operating voltage supply to sensors...

Страница 80: ...ween pins 4 2 socket upper row and Pin 2 socket lower row Advantage Two inputs on lower socket here I0 00 and I0 01 thereby fewer cables connection to changeover switch or converter possible Please no...

Страница 81: ...s above the relevant valve should be used clearer overview of the system Examples Valve cylinder combination with interrogation of limit switches via sensors Example 1 Connecting two sensors with two...

Страница 82: ...hle Germany Pin 1 2 4 3 Pin 1 4 3 Sensor 1 I0 08 Pin 1 4 3 Sensor 2 I0 09 Sensor 2 Sensor 1 Sensor 1 and 2 S S 2 1 must remain free Fig 4 32 Example 2 Connection of sensors with one socket Sensor 1 Pi...

Страница 83: ...VIFB8 02 4 Installation 4 48 9706...

Страница 84: ...5 COMMISSIONING VIFB8 02 5 Commissioning 9706 5 1...

Страница 85: ...ching on the operating voltage 5 5 Addressing the inputs and outputs 5 6 Valve terminal 5 6 Valve locations 5 6 Valve sensor terminal 5 8 Valve locations inputs and additional outputs 5 8 Status bits...

Страница 86: ...configuration list of the con nected RIO slaves On the basis of this list he can make a comparison between the ACTUAL and NOMINAL configurations in order to eli minate connection faults access specif...

Страница 87: ...len Bradley This corre sponds to a quarter rack in A B terminology with a maximum of 32 inputs and 32 outputs A special configuration software is not necessary The valve terminal evaluates only the ou...

Страница 88: ...he control system and valve terminal valve sensor terminal are supplied with power from a common source the devices should be switched on simultaneously by means of a central switch Separate power sup...

Страница 89: ...alve locations Two outputs are assigned to each valve location The designation of these outputs is noted on the valve terminal and is composed as follows Festo designation for Output O 1 05 Bit no in...

Страница 90: ...he valve locations Outputs of the valve locations No 0 No 1 No 2 No 3 No 4 No 5 No 6 No 7 No 8 No 9 Fig 5 2 Outputs of the valve locations Valve location no Valve type Output Bit con tents Remarks 2 s...

Страница 91: ...ts and two outputs are assigned to each valve location Two additional inputs out puts are arranged above the field bus node The designation of the inputs outputs is noted on the valve sensor terminal...

Страница 92: ...1 00 1 02 1 04 0 00 0 01 0 03 0 11 0 05 0 07 0 09 0 13 0 15 1 01 1 03 1 05 0 01 0 00 Additional inputs above the RIO node I0 00 and I0 01 Outputs of the valve locations O0 02 O1 05 Additional outputs...

Страница 93: ...valve solenoid coil not active Lower valve solenoid coil active Additional outputs SA0 O0 00 0 Additional output not active SA1 O0 01 1 Additional output active 24 V DC Fig 5 6 Example 1 Addressing a...

Страница 94: ...designations exist for the status bits Valve sensor terminal Designation Bit contents read Remarks Festo terminal A B Valve sensor terminal I1 14 I1 15 I011 14 I011 15 0 or 1 Meaning see Chap 6 Exampl...

Страница 95: ...rom Allen Bradley The addressing of the valve terminal valve sen sor terminal in the Allen Bradley RIO link de pends on the Allen Bradley programmable con troller used The addressing in an A B control...

Страница 96: ...O010 01 O010 02 O010 03 O010 04 O010 05 O010 06 O010 07 O010 10 O010 11 O010 12 O010 13 O010 14 O010 15 O010 16 O010 17 O011 00 O011 01 O011 02 O011 03 O011 04 O011 05 O011 06 O011 07 O011 10 O011 11...

Страница 97: ...n the SD or SD2 adapter Data transmission functions correctly With these controllers maximum 32 modules can be physically connected to one channel of the RIO PLC 2 family Terminal no I O rack no I O g...

Страница 98: ...PLC 5 250 PLC 3 4 5 6 7 8 9 10 11 12 13 14 15 1 1 1 1 2 2 2 2 3 3 3 3 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 0...

Страница 99: ...LC 5 60 PLC 5 250 PLC 3 40 41 42 43 44 58 59 60 61 62 63 12 12 12 12 13 16 16 17 17 17 17 0 1 2 3 4 5 6 7 0 1 4 5 6 7 0 1 2 3 4 5 6 7 64 65 66 67 68 90 91 82 93 94 95 20 20 20 20 21 26 26 27 27 27 27...

Страница 100: ...02 Terminal no I O rack no I O group 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 0 0 0 1 1 1 1 2 2 2 2 3 3 3 3 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 VIFB8 02 5 Commissioning 9706...

Страница 101: ...14 I0 15 I1 00 I1 01 I1 02 I1 03 I1 04 I1 05 I1 06 I1 07 I1 08 I1 09 I010 02 I010 03 I010 04 I010 05 I010 06 I010 07 I010 10 I010 11 I010 12 I010 13 I010 14 I010 15 I010 16 I010 17 I011 00 I011 01 I0...

Страница 102: ...6 7 8 9 O0 02 O0 03 O0 04 O0 05 O0 06 O0 07 O0 08 O0 09 O0 10 O0 11 O0 12 O0 13 O0 14 O0 15 O1 00 O1 01 O1 02 O1 03 O1 04 O1 05 O010 02 O010 03 O010 04 O010 05 O010 06 O010 07 O010 10 O010 11 O010 12...

Страница 103: ...mple Address 4 Example Address 5 Designator A B Valve location 10 11 12 13 O1 06 O1 07 O1 08 O1 09 O1 10 O1 11 O1 12 O1 13 O011 06 O011 07 O011 10 O011 11 O011 12 O011 13 O011 14 O011 15 O013 06 O013...

Страница 104: ...6 DIAGNOSIS AND ERROR TREATMENT VIFB8 02 6 Diagnosis error treatment 9706 6 1...

Страница 105: ...s 6 3 RIO node 6 3 Valves 6 5 Inputs and additional outputs 6 6 Diagnosis 6 7 Testing the valves and additional outputs 6 9 Reaction during faults 6 11 Short circuit overload at the additional output...

Страница 106: ...LEDs on the cover of the RIO node indicate the operating status of the valve terminal valve sensor terminal Green LED communication status Red LED operating status display BUS POWER Fig 6 1 LEDs on th...

Страница 107: ...c components not applied or hardware error Check operating voltage Green off No communication on RIO Check operating voltage configuration of RIO slave and correct if necessarry Green blinking Program...

Страница 108: ...ic 0 no signal Yellow on Switch position or Basic position Logic 1 signal exists Logic 1 but Operating voltage of outputs is below permitted tolerance range DC 21 6V 26 4V or Compressed air supply not...

Страница 109: ...show the signal which is currently at the input or output LED Status Yellow off or green off Logic 0 no signal Yellow on or green on Logic 1 signal exists Fig 6 4 LED display Switching status of the i...

Страница 110: ...of operating voltage connection 21 6V Voutput Vout Monitors the operating voltage of the valves and additional outputs no voltage e g EMERGENCY OFF Operating voltage at pin 2 of operating voltage con...

Страница 111: ...ir meaning is shown in the following diagram Valve sensor terminal type 02 Meaning A B I1 14 I1 15 I021 16 I021 17 e g Festo terminal has address 8 Bit sequenc e 0 0 No error 1 0 Vval 21 6V 0 1 Vinp 1...

Страница 112: ...of the connected actuators undefined switching states of the electronic components WARNING Before the test is started the following must be switched off or disconnected compressed air supply operatin...

Страница 113: ...Note the positions of the address selector switch and of the DIL switch elements 4 Set address 99 and set DIL switch elements 1 4 at OFF 5 Switch on the operating voltage 6 Set the desired test routi...

Страница 114: ...ions Reaction during faults The outputs are switched off in the following cases during transmission errors if the controller is set at position Program mode with a key if there is a cable fracture The...

Страница 115: ...opted If the short circuit has still not been eliminated the additional output will be switched off again Step Explanation Eliminate short circuit or overload Set additional output at 0 RESET Manual o...

Страница 116: ...INDEX VIFB8 02 Appendix A 9706 A 1...

Страница 117: ...VIFB8 02 Appendix A A 2 9706...

Страница 118: ...link 2 7 Auxiliary pilot air 4 13 B Base unit valve sensor terminal 3 5 valve terminal 3 3 Blind plug 4 8 4 11 C Commissioning 5 1 Common cable connections 3 4 3 6 Compressed air 4 10 Configuration p...

Страница 119: ...4 10 F Fitting valve terminal valve sensor terminal 4 1 4 3 Fuse for inputs 3 6 H Hold Last State 4 22 4 28 Hoses 4 8 I Input output words 5 8 Inputs 4 44 Inscription field inputs outputs 3 6 valve l...

Страница 120: ...ge 3 7 applying 4 34 switching on 5 5 Operating voltage connection 3 4 3 6 4 31 Operation and display elements 3 4 3 6 Output word 5 6 P Part number 3 7 Pilot exhaust 4 10 Pneumatic components install...

Страница 121: ...4 38 RIO link 3 8 RIO node 3 3 3 5 3 7 3 8 4 23 6 3 6 10 opening and closing 4 23 RIO scanner 3 8 RIO scanner ports 2 5 S Sensors 2 7 Setting the RIO address 4 25 Socket 4 43 Solenoid mid position val...

Страница 122: ...e 4 38 Type designation 3 7 Type plate 3 4 3 6 U User instructions 1 1 V Valve coupling unit 3 3 3 8 Valve locations 3 3 3 5 outputs 5 6 Valve sensor coupling unit 3 5 3 8 Valve terminal valve sensor...

Страница 123: ...VIFB8 02 Appendix A A 8 9706...

Отзывы: