Index.
Subindex
Name
Description
Data type
(length)
User access
1)
U = User
M = Maintenance
personnel
S = Specialist
U
W
S
–
Control command for switch-
ing on the power stage. The
current position Pos
Act
of the
drive is maintained position-
controlled.
0x0002.0
(2.0)
SystemCom-
mand
Value 0xCD (205): Restore fact-
ory settings
–
Control command to reset
the drive unit to factory set-
tings
è
–
After reset to the factory set-
tings, the drive must be ref-
erenced
è
UIntegerT
(1 byte)
–
W
W
1) R/W = read and write, R = read only, W = write only
Tab. 38 System parameters
14.2.5
Control end-to-end operation via IO-Link
The following table shows the combinations of the process parameters "Mov
In
" and "Mov
Out
" or the
system parameter "System Commands" via IO-Link for controlling the drive in end-to-end operation.
Process parameters
System parameters
Description
"Mov
In
"
"Mov
Out
"
System commands
0x0029.1
0x0029x2
0x0002
false
false
Stop motion
0xCA
(202)
Control command for stopping travel.
–
The power stage remains active.
–
The drive decelerates to standstill.
–
The drive remains at position-controlled
standstill.
false
true
Mov
Out
0xC9
(201)
Control command for executing the motion
"Mov
Out
".
–
The drive moves position-controlled
towards the "Lim
Out
" end position.
IO-Link
76
Festo — EMCS-ST — 2020-04a
Содержание EMCS-ST
Страница 1: ...8123666 EMCS ST Integrated drive 8123666 2020 04a 8123668 Operating instructions ...
Страница 29: ...11 1 2 Dimension reference system Drive system 29 Festo EMCS ST 2020 04a ...
Страница 48: ...Fig 22 Single end to end operation Drive system 48 Festo EMCS ST 2020 04a ...
Страница 50: ...Fig 23 Stop and continue single end to end motion Drive system 50 Festo EMCS ST 2020 04a ...
Страница 54: ...Fig 25 End to end operation with press function Drive system 54 Festo EMCS ST 2020 04a ...
Страница 56: ...Fig 26 Stop and resume end to end travel with press function Drive system 56 Festo EMCS ST 2020 04a ...