Festo EMCS ST Series Скачать руководство пользователя страница 6

Steps for updating the parameter set

8. Eliminate incompatibility errors. Only if the error in question is displayed.

With error message "Parameter package download error - parameter set incompatible".

Restart the drive with power OFF/ON at the logic power supply 24 V DC [Pin 1].
Upload the parameter set to the integrated drive again and update it in the drive.

è

 5. Upload the parameter set file to the integrated drive.

è

 6. Update the parameter set file in the integrated drive.

Open the ‘Specialist (user role)’ 

1

 tab.

Open the ‘Parameters’ 

2

 and ‘Save parameters’ 

3

 submenus.

In the ‘Save parameters’ parameter press the ‘Save parameter’ 

4

 button.

9. Acknowledge error (only if an error is pending)

Open the "Specialist (user role) 

1

" tab

Open submenus "Parameter 

2

" and "Control parameter 

3

Press the "Acknowledge error 

4

" button

10. Check current status of the parameter set

Open the "Identity 

1

" tab

Check the current device ID in the "Device 

2

" parameter. The device ID must correspond to the

drive system in use

0x000259 (601): ELGS-TB

0x00025A (602): ELGS-BS

0x00025B (603): EGSS-BS

0x00025C (604): ELGE-TB

0x00025E (606): EPCS-BS

With 0x000258 (600), EMCS-YY-ST spare part, the parameter set file was not updated successfully.
Repeat the sequence from step "4. Open parameter set file".

Steps for updating the parameter set

11. Initialise end positions "Lim

In

/ Lim

Out

" and reference end position "Ref"

Open the "Specialist (user role) 

1

" tab

Open the "Parameter 

2

" and "System commands 

3

" submenus

Execute the default command ""Reference" movement" 

4

Press one of the two following buttons for the default commands:

Execute "Reference" movement (False) 

4

 (factory setting, motor-facing reference end position

"Ref")

Execute "Reference" movement (True) 

5

 (reference end position "Ref" motor facing away)

12. Save parameter set as factory setting

Open the "Specialist (user role) 

1

 tab

Open the "Parameter 

2

" and "File handling commands 

3

" submenus

In the "Activate file handling" parameter activate the "Activate file handing 

4

" value and press

the "Write 

5

" button

In the "Execute file handling" parameter select the "Overwrite factory settings 

6

" value and

press the "Write 

7

" button

1) The use of the function depends on the application software.

Tab. 8: Steps for updating the parameter set

Diagnostic messages when updating the parameter set
The table shows all diagnostic messages that may be shown when updating the
parameter set.

Event code Description

LED

Error code

(IO-Link)

C/Q

hex (dec)

0x1820

Parameter set not found

red light

0x0061
(97)

Remedy

Check parameter set selection

0x1821

Parameter set invalid

0x0062
(98)

Remedy

Overwrite parameter set (save) 

è

 Tab. 8

Steps for updating the parameter set, 8. Elim-
inate incompatibility error.

0x1822

Parameter set incompatible

0x0063
(99)

Remedy

Overwrite parameter set (save) 

è

 Tab. 8

Steps for updating the parameter set, 8. Elim-
inate incompatibility error.

0x1823

Parameter not found

0x0064
(100)

Remedy

Overwrite parameter set (save) 

è

 Tab. 8

Steps for updating the parameter set, 8. Elim-
inate incompatibility error.

Tab. 9: "Parameter set error" diagnostic messages