F
Diagnostics and fault clearance
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
377
F.1.8
EtherCAT display component
The status of EtherCAT is displayed over the following four LEDs.
LED
Function
Status
Significance
EC ERROR
EC RUN
EC LINK/
ACTIVITY
Port 2
EC LINK/
ACTIVITY
Port 1
EC
LINK/
ACTIV
ITY
Communica
tion activity/
Line monitor
ing
Off
No link / bus activity present
Illuminated
green
Link present
Flickers green
Bus activity present
EC
RUN
Operating
status
Off
Current status “Init”
Flashes green
Current status “Pre-Operational”
Flashes green
once
Current status “Safe-Operational”
Illuminated
green
Current status “Operational”
EC
ERROR
Faults
Off
No error
Flashes red
Invalid Configuration: General con
figuration error was triggered
Flashes red
once
Unsolicited state change: Local error
was triggered
Flashes red
twice
Application Watchdog Timeout:
Sync Manager Watchdog was
triggered
Flickers red
Booting error:
Boot error was triggered during the
boot process
Illuminated
red
Missing process data communica
tion (PDI (Process Data Interface)
Watchdog Timeout)
PDI Watchdog error was triggered
1)
A status change specified by the controller is not possible due to register or object settings.
2)
The EMCA application/The EMCA has changed the EtherCAT status autonomously:
A) A Host/Steuerung Watchdog Timeout has occurred
B) Synchronization error, the EMCA changes automatically after Safe-Operational
Tab. F.5
LED indicator
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......