background image

Error
code

Description

LED

LED displays

Event
code

hex
(dec)

C/Q

Menu

Parameter

(IO-
Link)

0x012F
(303)

IO-Link connection inter-
rupted
IO-Link connection inter-
rupted

z

Remedy

Check power supply

Check IO-Link master

1) Additional information 

è

 Instruction manual for integrated drive EMCS-ST

2) This error can only be acknowledged by a restart.

Tab. 7: "Information, warnings and errors" diagnostic messages

10.1

Repair

The product can be repaired or maintained.

Spare parts and accessories 

è

 www.festo.com/spareparts.

Replace with an identical product 

è

 www.festo.com/catalogue.

11

Replacement

Replace drive system
1. Save the application parameters to the IO-Link master 

è

 "Integrated drive

EMCS" instruction manual 

è

 www.festo.com/sp.

2. Dismantle the defective drive system 

è

 12 Disassembly.

3. Mount the new drive system 

è

 6 Assembly.

4. Connect the drive system 

è

 7 Installation.

5. Commission the drive system 

è

 8 Commissioning.

6. Update the firmware 

è

 "Integrated drive EMCS" instruction

manual 

è

 www.festo.com/sp.

7. Check the current status of the application data 

è

 "Integrated drive EMCS"

instruction manual 

è

 www.festo.com/sp.

Replace drive or integrated drive EMCS 

è

 "Integrated drive EMCS" instruction

manual 

è

 www.festo.com/sp.

12

Disassembly

WARNING

Unexpected movement of components.
Injury due to impacts or crushing.
• Before working on the product, switch off the control and secure it to prevent it

from being switched back on accidentally.

WARNING

Risk of Injury due to Unexpected Movement of Components
For vertical or slanted mounting position: when power is off, moving parts can
travel or fall uncontrolled into the lower end position.
• Bring moving parts of the product into a safe end position or secure them

against falling.

Disassemble drive system
1. Allow the product to cool down to room temperature.
2. Disconnect electrical installations.
3. Remove the mounted attachment component.
4. Remove the attached accessories.
5. Remove the mounting attachments.
6. Observe transport information 

è

 5 Transport.

Remove drive or integrated drive EMCS 

è

 "Integrated drive EMCS" instruction

manual 

è

 www.festo.com/sp.

13

Technical data

Additional information 

è

 www.festo.com/catalogue.

Size

35

Mounting position

horizontal

Ambient temperature

[°C]

0 … +50

Storage temperature

[°C]

–20 … +60

Degree of protection

IP20

CE marking

è

 Declaration of Conformity

in accordance with EU EMC Directive
in accordance with EU RoHS Directive

Max. payload

horizontal mounting posi-

tion

[kg]

2.8

Max. velocity

1)

[mm/s]

1200

2)

Velocity "Speed Press"

[mm/s]

24

Max. feed force

3)4)

[N]

50

Max. force on external stops
during referencing

5)

[N]

50

Acceleration/deceleration

[m/s

2

]

8.5

Duty cycle

[%]

100 (+30 … +50 °C: – 2% per kelvin)

Distance between stop and
end position

6)7)

[mm]

2

Repetition accuracy

[mm]

±0.1

Nominal voltage

[V DC]

24

Size

35

Logic current consumption
(logic, pin 1)

[mA]

DIO operation: 100 ... 300
IO-Link operation: 100 ... 150

Load current consumption
(power, pin 1)

[A]

5.3

1) Maximum value for Speed In/Speed Out at level 10
2) Can only be achieved from a stroke of 250 mm.
3) Maximum value for Force at level 10
4) Force is controlled and evaluated by closed-loop control of the motor current. Depending on the mecha-

nism of the drive, a linear force can be determined from the level of current measured. The target is set as
a percentage of the rated motor current and may deviate from the actual force on the axis. At the lowest
force levels the frictional force of the drive system may be greater than the set feed force and result in the
drive system coming to a standstill.

5) The force acts on the stop for 

£

100 ms

6) Distance (MechIn – LimIn or MechOut – LimOut)
7) The specified value can deviate due to the elasticity of the toothed belt.

Tab. 8: Technical data ELGE-TB

Содержание ELGE-TB

Страница 1: ...ntact the regional Festo contact if you have technical problems è www festo com Accessories and spare parts è www festo com catalogue 4 Product overview 4 1 Scope of delivery The following components are included in the scope of delivery Toothed belt axis unit ELGE TB Instruction manual for the toothed belt axis unit ELGE TB Adapter for IO Link operation optional accessory è www festo com catalogu...

Страница 2: ...V Low level 0 V Tab 2 Overview of status and control signals as a function of electrical levels Wiring diagram IO Link operation port class A with and without NEFC adapter Current consumption of IO Link power supply Logic An input current at pin 1 L of 100 150 mA is required for operation 1 2 3 Fig 6 Wiring diagram IO Link operation 1 PELV fixed power supply for the load voltage supply 2 Integrate...

Страница 3: ...imOut reference point reference end posi tion Ref 0x0108 0 intermediate position PosImp reference point reference end position Ref additional parameters for point to point operation with press function 0x0102 0 Force 0x0105 0 start press position PosStart Press reference point reference end position Ref Then the EMCS ST is ready for operation and the application can be controlled via the IO Link i...

Страница 4: ...x0103 0 false factory setting or true and initiate referencing movement 0x0104 0 true IO Link system parameter 0x0002 value 0xCE Execute Reference Movement False factory setting or value 0xCF Execute Reference Movement True Sequence The diagram shows the referencing movements with end position determination MovRef force controlled movement against mechanical stop MechIn MovOut position controlled ...

Страница 5: ... remedied before acknowledgment Errors can be acknowledged via the following interfaces Restart Logic voltage L Power OFF ON Logic Pin 1 HMI Press and hold for 3 s DIO digital inputs DI1 MovIn and DI2 MovOut 1 Logic Pin 5 6 IO Link device data 0x0107 0 Quit Error true IO Link process data 0x0029 3 Quit Error true 0x0029 1 and 0x0029 2 true 0x0029 5 any Diagnostic messages and fault clearance Infor...

Страница 6: ... system 1 Allow the product to cool down to room temperature 2 Disconnect electrical installations 3 Remove the mounted attachment component 4 Remove the attached accessories 5 Remove the mounting attachments 6 Observe transport information è 5 Transport Remove drive or integrated drive EMCS è Integrated drive EMCS instruction manual è www festo com sp 13 Technical data Additional information è ww...

Отзывы: