background image

10

Malfunctions

Acknowledge error
With error acknowledgment, active error messages are deleted from the diag-
nostic memory if the cause of the error was remedied before acknowledgment.
Errors can be acknowledged via the following interfaces:

Restart:

Logic voltage L

+

, Power OFF/ON [Logic, Pin 1]

HMI:

Press and hold 

 for 3 s

DIO, digital inputs:

DI1 "Mov

In

" and DI2 "Mov

Out

" = 1 [Logic, Pin 5/6]

IO-Link, device data:

0x0107.0 Quit Error = true

IO-Link, process data:

0x0029.3 Quit Error = true

0x0029.1 and 0x0029.2 = true, 0x0029.5 = any

Diagnostic messages and fault clearance
"Information, Warnings and Errors" diagnostic messages are displayed by the
C/Q LED and menu and parameters LED displays.
Errors are reported to the controller as follows:

DIO operation: output signals DO1 and DO2 = 1 [Logic, Pin 2/3]

IO-Link operation: ProcessDataInput state "In" (0x0028.1) and state "Out"
(0x0028.2) = true

The first error that occurred is always displayed.

Fig. 9: Display of diagnostic messages (example)

Error
code

Description

LED

LED displays

Event
code

hex
(dec)

C/Q

Menu

Parameter

(IO-
Link)

Warning

z

Warnings

1)

yellow
light

z

0x...

Errors

z

Common device error or
unlisted errors

red light

0x100
0

Remedy

Contact Festo

0x000F
(15)

I

2

t monitoring output stage

error limit

0x180
5

Remedy

0x0016
(22)

Undervoltage in logic supply
24 V

2)

0x180
4

Remedy

Check logic voltage supply

0x0017
(23)

Overvoltage in logic supply
24 V

0x180
3

Remedy

Check logic voltage supply

0x001F
(31)

Undervoltage in intermediate
circuit

0x180
6

Remedy

Check the load voltage
supply

Check power socket for
contamination

0x0026
(38)

Undervoltage in load supply
24 V

0x180
2

Remedy

Check the load voltage
supply

Check power socket for
contamination

0x0027
(39)

Overvoltage load supply 24 V

0x180
1

Remedy

Check the load voltage
supply

0x0031
(49)

Temperature in device too
low

0x400
0

Remedy

Check ambient conditions

Error
code

Description

LED

LED displays

Event
code

hex
(dec)

C/Q

Menu

Parameter

(IO-
Link)

0x0033
(51)

Temperature in device too
high

0x400
0

Remedy

Check ambient conditions

Check installation condi-
tions

0x012F
(303)

IO-Link connection inter-
rupted
IO-Link connection inter-
rupted

z

Remedy

Check power supply

Check IO-Link master

1) Additional information 

è

 Instruction manual for integrated drive EMCS-ST

2) This error can only be acknowledged by a restart.

Tab. 7: "Information, Warnings and Errors" diagnostic messages

10.1

Repair

The product can be repaired or maintained.

Spare parts and accessories 

è

  www.festo.com/spareparts.

Replace with an identical product 

è

  www.festo.com/catalogue.

11

Replacement

Replace drive system
1. Save the application parameters to the IO-Link master 

è

 "Integrated drive

EMCS" instruction manual 

è

  www.festo.com/sp.

2. Dismantle the defective drive system 

è

 12 Demounting.

3. Mount the new drive system 

è

 6 Assembly.

4. Connect the drive system 

è

 7 Installation.

5. Commission the drive system 

è

 8 Commissioning.

6. Update the firmware 

è

 "Integrated drive EMCS" instruction

manual 

è

  www.festo.com/sp.

7. Check the current status of the application data 

è

 "Integrated drive EMCS"

instruction manual 

è

  www.festo.com/sp.

Replace drive or integrated drive EMCS 

è

 "Integrated drive EMCS" instruction

manual 

è

  www.festo.com/sp.

12

Demounting

WARNING

Unexpected movement of components.
Injury due to impacts or crushing.
• Before working on the product, switch off the control and secure it to prevent it

from being switched back on accidentally.

WARNING

Risk of Injury due to Unexpected Movement of Components
For vertical or slanted mounting position: when power is off, moving parts can
travel or fall uncontrolled into the lower end position.
• Bring moving parts of the product into a safe end position or secure them

against falling.

Demount drive system
1. Allow the product to cool down to room temperature.
2. Disconnect electrical installations.
3. Remove the mounted attachment component.
4. Remove the attached accessories.
5. Remove the mounting attachments.
6. Observe transport information 

è

 5 Transport.

Remove drive or integrated drive EMCS 

è

 "Integrated drive EMCS" instruction

manual 

è

  www.festo.com/sp.

13

Technical data

Additional information 

è

  www.festo.com/catalogue.

Содержание EGSS-BS

Страница 1: ... personnel have knowledge and experience in dealing with electric drive systems 3 Additional information Contact the regional Festo contact if you have technical problems è www festo com Accessories and spare parts è www festo com catalogue 4 Product overview 4 1 Scope of delivery The following components are included in the scope of delivery Mini slide unit EGSS Instruction manual for the mini sl...

Страница 2: ...he logic power supply 3 Integrated drive EMCS ST 4 Higher level controller with dig ital I O Status and control signals The following table shows the status and control signals and the electrical levels of the digital inputs and outputs as a function of the PNP NPN version of the integrated drive Status and control signal Electrical levels PNP positive logic NPN negative logic 0 Low level 0 V High...

Страница 3: ...erence end position Ref from the IO Link device data 0x0103 0 reference and start the homing with end position detection 0x0104 0 Execute Reference Movement only required if the reference end position Ref is different from the factory setting or if the useful range has been changed The drive system is referenced after a successful homing Homing sets the PosImp intermediate position and the PosStar...

Страница 4: ...tartRef PosAct è LimIn è LimOut press Run Start Press movement Start Stop and save Start Press Position PosStart Press Save press Execute demo run Start Stop Lock pushbutton actuators Lock HMI press and hold for 3 s or no push button actuator input for 15 s To acknowledge an error press and hold for 3 s Reset to factory settings press and simultaneously for 10 s and then carry out a Power OFF ON o...

Страница 5: ...y Speed Out 0x0101 0 Speed Out1 Velocity Speed In 0x0100 0 Speed In1 Force Torque 0x0102 0 Force1 2 Start Press Position PosStart Press 0x0105 0 Position Start Press mm 2 3 4 End position LimOut 0x0106 0 end position Out mm 4 Intermediate position PosImp 0x0108 0 Intermediate Position mm 3 4 Control point to point operation via digital inputs Positioning task Control signals MovIn DI1 Logic Pin 5 ...

Страница 6: ...too high 0x400 0 Remedy Check ambient conditions Check installation condi tions 0x012F 303 IO Link connection inter rupted IO Link connection inter rupted z Remedy Check power supply Check IO Link master 1 Additional information è Instruction manual for integrated drive EMCS ST 2 This error can only be acknowledged by a restart Tab 7 Information Warnings and Errors diagnostic messages 10 1 Repair ...

Страница 7: ... 24 Logic current consumption logic pin 1 mA DIO operation 100 300 IO Link operation 100 150 Load current consumption power pin 1 A 3 3 5 3 IO Link port class A IO Link protocol version Device V 1 1 1 Maximum value for Speed In Speed Out at level 10 2 Unchangeable parameter 3 Maximum value for Force at level 10 4 Force is controlled and evaluated by closed loop control of the motor current Dependi...

Отзывы: