![Festo EasyPort USB D16A Скачать руководство пользователя страница 137](http://html.mh-extra.com/html/festo/easyport-usb-d16a/easyport-usb-d16a_manual_2283214137.webp)
9. EasyPort USB command interpreter
© Festo Didactic GmbH & Co. KG „ 721876
137
Example of a read command (display)
Description: display input bit 5 from word 0 in EasyPort USB module 1.
A
display command
consists of a command letter, a resource and the
resource’s data type. Along with indication of the model number, the
address of the resource follows the word address and, if applicable, the
byte or bit address. The individual address entries are separated by
periods.
Example of a write command (modify)
Command
Description
MA2.0.C=1
Change output bit 12 from word 0 in EasyPort USB
module 2 to 1
Modify commands
must be provided with a data value. The data value
follows the resource address and is preceded with an equal sign.
Please note
: Address numbers and data values must always be entered
in hexadecimal format.