background image

1. Turn the upstream one-way flow control valve of the semi-rotary drive and inter-

mediate position completely closed and open it back up one rotation.

2. Pressurize the system and the product.
3. Start a test run with low swivel frequency.
4. Turn all one-way flow control valves open one additional rotation until the de-

sired speed of the end position and intermediate position is reached. This can
be the case at different times.

6

Operation

Note

The intermediate-position module can be destroyed if it runs against an unpres-
surised chamber.
• Make sure that the chamber from the previous operating status is pressurized

at the semi-rotary drive. Only when the valves are reversed simultaneously is
an air cushion present in the chamber, which makes the function of the ex-
haust air flow control valve possible.

7

Technical data

Size

16

20

25

32

35

40

50

Mass moment of inertia (swivelling into intermediate position)

P (min.)

[kgcm

2

]

0

0

0

0

P (max.)

[kgcm

2

]

150

300

400

500

Y9/Y12 (min.)

[kgcm

2

]

15

40

100

100

500

1000

2000

Y9/Y12 (max.)

[kgcm

2

]

500

900

1500

8000

15000

23000

40000

Max. perm. swivel time

(

www.festo.com/catalogue)

Pneumatic port

M5

G1/8

Operating pressure range

P

[bar]

4 … 8

Y9/Y12

[bar]

2 … 10

Swivel angle

Intermediate position

[°]

90 ±10

End positions

[°]

0 … 80; 100 … 180

Materials

Housing, cover

Anodised aluminium

Dampener,

Steel, NBR

Sleeves

Stainless steel

Weight (total load)

P

[kg]

1.10

1.47

2.35

5.0

Y9

[kg]

1.12

1.53

2.41

5.28

8.51

10.52

19.12

Fig. 12