Festo Distributing Station Скачать руководство пользователя страница 3

 

© Festo Didactic GmbH & Co. KG • MPS 

3

 

6

"start"

 indicator 

light

A 9

5

empty step:

cycle start

7

empty step:

downstream

station free

C 16

turn on "start" 

indicator light

station is reset

and in initial position

sequential function chart according to DIN EN 60848 (IEC 60848) for the Distribution station

1-bit-link

flag "start" is not set

flag "start" is set

downstream station free

2

"reset"

indicator

light

3

initial-

position

4

reset

ok

turn on "reset"

indicator light

move station 

to initial position

set flag "reset finished"

station is not reset

flag "start" is set

"reset" button pressed

flag "reset finished"is set

station in initial position

1

Start

8

swivel arm

to position

"downstream

station"

swivel arm to position 

"downstream station"

swivel arm to position "downstream station"

 

 

Function chart Distributing station 