background image

14

Dismantling

Note

Disassembly only by qualified personnel.

1. Switch off the energy supply (compressed air, electricity)
2. Loosen the pneumatic connections.
3. Remove external attachments.
4. Loosen the mounting screws of the drive at the process valve and remove the

drive.

15

Disposal

 Observe the local regulations for environmentally friendly disposal.
 Dispose of the product in an environmentally friendly manner. When doing this,

also take residual media into account
(potential recycling of hazardous waste).

16

Technical data

General

DFPD

DFPD-...-T4

DFPD-...-T6

Standard connection to the process valve

ISO 5211

Cushioning

None

Mounting position

Any

Design

Rack and pinion principle

Valve connection conforms to standard

VDI/VDE 3845 (NAMUR)

Swivel angle

DFPD-...-90

[°]

0…90

DFPD-...-120

[°]

0…120

DFPD-...-135

[°]

0…135

DFPD-...-180

[°]

0…180

End position adjustment range 0°

[°]

± 5

End position adjustment range 90° /
180°

[°]

± 5

Operating pressure

[bar]

2…8

3…8

3…8

Nominal operating pressure

DFPD-...-RD, DFPD-...-LD
DFPD-...-...S-20
DFPD-...-...S-25
DFPD-...-...S-30
DFPD-...-...S-35
DFPD-...-...S-40
DFPD-...-...S-45
DFPD-...-...S-50
DFPD-...-...S-55
DFPD-...-...S-60

[bar]
[bar]
[bar]
[bar]
[bar]
[bar]
[bar]
[bar]
[bar]
[bar]

5.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0

Operating medium

Compressed air according to ISO8573-1:2010 [7:4:4]

Note on the operating medium

Pressure dew point at least 10 °C below outside
temperature, lubricated operation possible (re­
quired in further  operation)

Ambient temperature

[°C]

20…+80

0…+150

50…+60

CE marking (declaration of conformity

è

 www.festo.com/sp)

To EU Explosion Protection Directive (ATEX)

1)

Material

Housing

Anodised wrought aluminium alloy

Cap

Coated die-cast aluminium

Shaft

Steel, nickel-plated
Stainless steel (only R3 variant)

Screws

Stainless steel

Seal

NBR

FPM

FVMQ

1)

Take into account certification-specific documentation 

è

 www.festo.com/sp

Fig. 14

Type

Air consumption per cycle at an operating pressure of
6 bar

1)

DFPD-10-RP-90-D

[l]

0,54

DFPD-20-RP-90-D

[l]

1,21

DFPD-20-RP-90-S

[l]

0,60

DFPD-40-RP-90-D

[l]

2,47

DFPD-40-RP-90-S

[l]

1,80

DFPD-40-RP-180-D

[l]

4,80

DFPD-80-RP-90-D

[l]

5,30

DFPD-80-RP-90-S

[l]

3,60

DFPD-120-RP-90-D

[l]

7,80

DFPD-120-RP-90-S

[l]

5,40

DFPD-120-RP-180-D

[l]

14,40

DFPD-160-RP-90-D

[l]

10,80

DFPD-160-RP-90-S

[l]

7,20

DFPD-250-RP-90-D

[l]

15,60

DFPD-240-RP-90-S

[l]

10,20

DFPD-240-RP-180-D

[l]

28,20

DFPD-300-RP-90-D

[l]

26,40

DFPD-300-RP-90-S

[l]

13,20

DFPD-480-RP-90-D

[l]

40,20

DFPD-480-RP-90-S

[l]

21,00

DFPD-480-RP-180-D

[l]

66,60

1)

Theoretical value for a complete swivel motion (0° - max. swivel angle - 0°)

Fig. 15

Содержание DFPD-x-RS Series

Страница 1: ...Complete the declaration of contamination and attach it to the outside of the packaging Comply with all legal requirements for handling hazardous substances and transporting dangerous goods 3 Intended use The DFPD quarter turn actuator is intended to actuate process valves such as ball valves and butterfly valves with a rotation angle from 0 valve closed to 180 depending on design Note The operati...

Страница 2: ...g 3 2 The end stops can be adjusted in the range 5 through the end position adjust ment on both sides è Fig 3 9 7 2 Product variants and type code Fig 4 explains selected product characteristics that are necessary to un derstand the instructions Description of the complete type code è www festo com catalogue Characteristic Value Description Type DFPD Quarter turn actuator System of units N Metric ...

Страница 3: ...of dirt Type Compres sed air con nection Effect DFPD RS DFPD LS 2 Air supply always connected 4 Pressurisation of spring space Fig 11 Double acting quarter turn actuators Type Compres sed air con nection Effect DFPD RD 2 Direction of rotation of air supply anti clockwise1 4 Direction of rotation of air supply clockwise1 DFPD LD 2 Direction of rotation of air supply clockwise1 4 Direction of rotati...

Страница 4: ...0 3 5 4 0 4 5 5 0 5 5 6 0 Operating medium Compressed air according to ISO8573 1 2010 7 4 4 Note on the operating medium Pressure dew point at least 10 C below outside temperature lubricated operation possible re quired in further operation Ambient temperature C 20 80 0 150 50 60 CE marking declaration of conformity è www festo com sp To EU Explosion Protection Directive ATEX 1 Material Housing An...

Отзывы: