A
Technical appendix
90
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English
Positioning system with CMAX
Axes per string
1
Max. total length (all cables)
[m]
30
Electrical connection, control interface
–
5-pin
–
M9
–
Socket
Control interface
Data
CAN Bus with Festo protocol
(Integrated terminating resistor)
Operating modes
–
Record mode
–
Direct mode
–
Commissioning
–
Parameterisation
Record selection
–
Number of records
–
Record modes
128 (from FW V2.3), 64 (to FW 2.2)
–
Single position set
–
Configurable record sequencing
Direct mode
–
Modes
–
Point to point
–
Continuous following (not for force control)
Regulating function
–
Position control
–
Force control
Performance data
Repetition accuracy of position control
è
Repetition accuracy of force control
[%]
2 (of the maximum force)
Display
7-segments display
Status display (LED)
P
= Module status (error)
PL = Power load
Dx = Display/error axis X
X = MC axis X
Diagnostics
–
–
Via local 7-segments display
–
With FCT plug-in CMAX
–
Through the higher-order controller
Commissioning
–
With FCT plug-in CMAX
–
Through the higher-order controller
1)
Undervoltage monitoring, valve and sensor monitoring, storage of the last 100 diagnostic messages, operating hour counter
Tab. A.3