6
Diagnostics and error handling
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English
87
6.5
Diagnostic functions with the CPX-MMI
Parameterisation and commissioning via FMT or CPX-MMI is not supported. Representa
tion of the CMAX corresponds thereby to that of an I/O module. The subsequently de
scribed basic information is available.
General information on operating and commissioning the CPX terminal with the operator
unit CPX-MMI-1
è
Description for the operator unit, P.BE.CPX-MMI-1-....
6.5.1
Error display (menu [Diagnostics] )
Modules which report an error are marked in the main menu by an exclamation mark (!) in front of the
module number. In the menu [Diagnostics], errors present are displayed as input channel errors.
System Overview _
CPX terminal
0: ... Module ...
1: ... Module ...
!
2: CMAX-C1-1 1 Ser
ð
3: ... Module ...
_____________________________________________________
Diag
ßà
OK
2:CMAX-C1-1 _
Monitoring/forcing (M)
Diagnostics (D)
Parameters (P)
Module data (MD)
_____________________________________________________
Back OK
2:CMAX-C1-1 :D _
Channel fault:
Ch 0: Input
Configuration error
______________________________________________________
Back
ßà
1
2
3
1
Error present
2
Menu [Diagnostics]
3
Error number and description
Fig. 6.3
Error display with the CPX-MMI
Errors of the CMAX cannot be acknowledged with the CPX-MMI.