4.2 Locating faults
Impairment of function
When you switch on the compressed air supply or
when you have tested the individual valves, you can
learn the following about the operating status of the
pneumatic system.
Operating status of the
pneumatic system
Valve position
Error treatment when compressed
air has been switched off
Air comes out...
– of common tubing
connections
– of work tubing connections
– between the modules
– basic position
– switch position
– basic position
•
Check the seal or
tubing fitting
•
When switching on again regulate
separate auxiliary pilot air 3 to 8
bar
Valve or pneumatic system
– does not react as expected
– does not react
– does not react
– switch position
– switch position
– basic position
•
Check tubing
•
When switching on again,
check operating pressure
(e.g. pressure zones)
•
Return for servicing
– Check regulator connection
(apply pressure > 3 bar to
regulator)
4. Commissioning
4-10
CPV... 9811d
Содержание CPV -VI Series
Страница 1: ...Compact Performance CPV valve terminal Pneumatics Typ CPV VI...
Страница 2: ......
Страница 4: ...Part no 165 200 Title MANUAL Designation P BE CPV GB II CPV 9811d...
Страница 15: ...Chapter 1 System overview 1 System overview CPV 9811d 1 1...
Страница 31: ...Chapter 2 Fitting 2 Fitting CPV 9811d 2 1...
Страница 53: ...Chapter 3 Installation 3 Installation CPV 9811d 3 1...
Страница 69: ...Chapter 4 Commissioning 4 Commissioning CPV 9811d 4 1...
Страница 83: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPV 9811d 5 1...
Страница 106: ...5 Maintenance and conversion 5 24 CPV 9811d...
Страница 107: ...Appendix A Technical appendix A Technical appendix CPV 9811d A 1...