Configuration

Caution

The CPV Direct contains electronically sensitive compo­
nents. The CPV Direct will be damaged if you touch the
contact surfaces of the plug connectors and if you do
not observe the regulations for handling electrostati­
cally sensitive components.

Proceed as follows when configuring:

1. Switch off the power supply.

2. Remove the switch module.

3. Set the following with the DIL switches: field bus pro­

tocol, extension to the CP system, field bus address/
station number, diagnostic mode (only  PROFIBUS or
ABB CS31), baud rate (only Festo field bus).

4. Refit the switch module.

5. If the CP system is the first or last slave in a field bus

segment, the terminating resistor in the Festo Sub-D
plug must be activated.

Warning

S

Make sure that switch-on test pulses are sup­
pressed/switched off when you operate the CPV 
Direct via a “safety I/O module”.

S

Check the measures required for putting your system
into a safe status in the event of an EMERGENCY
STOP.

Further information can be found in manual 
P.BE-CP-DI01-...

Содержание CPV..-DI01 series

Страница 1: ...Brief description CPV valve termi nal with direct connection type CPV DI01 English 8080242 2017 11c 8080235 Compact Performance...

Страница 2: ...tra e 82 73734 Esslingen Germany Internet http www festo com E Mail service_international festo com Reproduction distribution or sale of this document or communication of its contents to others withou...

Страница 3: ...re connecting or disconnecting plugs otherwise this could lead to functional damage S Use power supplies which guarantee reliable electri cal isolation of the operating voltage as per IEC DIN EN 60204...

Страница 4: ...Ds 4 Switching status display of CP valve coils 5 CP extension connection 6 Switch module removed 1 2 3 4 5 6 Pin assignment of power supply connection M12 connection Pin no 1 24 V DC operating voltag...

Страница 5: ...h connection pin 4 max 3 A PS MNS 3 1 2 4 1 2 3 4 2 2 A 2 A Pin assignment of field bus connection Sub D 9 socket PROFIBUS DP Festo field bus ABB CS31 SUCOnet K Pin 3 B RxD TxD P S Bus 1 TA RA Pin 8 A...

Страница 6: ...switches field bus pro tocol extension to the CP system field bus address station number diagnostic mode only PROFIBUS or ABB CS31 baud rate only Festo field bus 4 Refit the switch module 5 If the CP...

Страница 7: ...t K 4 2 Setting the extension of the CP system 4 element DIL switch Extension to the CP system Setting the DIL switches CPV Direct without extension CPV Direct extended with a CP input module CPV Dire...

Страница 8: ...r 8 element DIL switch PROFIBUS DP ABB CS31 SUCOnet K 8 element DIL switch switch elements 1 7 Festo field bus 8 element DIL switch switch elements 1 6 Coded entry Example Station number 38 2 0 1 2 1...

Страница 9: ...Device related diagnosis active inactive ABB CS31 Load voltage monitoring active inactive Diagnosis ON Diagnosis OFF 4 5 Set the field bus baud rate only Festo field bus 8 element DIL switch 31 25 kB...

Страница 10: ...minal always occupies 16 output addresses A CP valve location occupies two addresses lower value address pilot solenoid 14 higher value address pilot solenoid 12 2 CP valve terminals electric input or...

Страница 11: ...IEC DIN EN 60204 1 by means of PELV circuits Protective Extra Low Voltage Protection against explosion as per EU guideline 94 9 EG EN 50021 and EN 50281 1 1 Do not disconnect electrical connec tions...

Страница 12: ...2 Load voltage connection Rated value Tolerance Current consumption 24 V DC protection against incorrect polarity fused in ternally switches on again automatically 20 4 26 4 V Sum of all switched on...

Отзывы: