Festo CPV..−GE−IP−8 0211NH English
17
5
Technical specifications
Type
CPV..−GE−IP−8
Temperature range
Operation
Storage
− 5 ... + 50° C
− 20 ... + 70 °C
Relative humidity
95 %, non−condensing
Protection class
as per EN 60529 plug
connector inserted or provided with
protective cap
IP65
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204−1/IEC 204)
With a PELV power unit
(Protected Extra Low
Voltage)
Protection against explosion
(as per EU guideline 94/9/EG,
EN 50021 and EN 50281−1−1). Do not
disconnect electrical connections which
are under tension.
II 3 G/D EEx nA II T5 X
−5 °C
Ţ
Ta +50 °C
T 80 °C IP65 (year of manu
facture see Ex−identification
on the product)
Electromagnetic compatibility
Interference emitted
Resistance to interference
Tested as per EN 61000−6−4
(industry)
*)
Tested as per EN 61000−6−2
(industry)
*)
The CPV Direct is intended for use in industrial installations.