![Festo CMMP Series Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/festo/cmmp-series/cmmp-series_manual_2283112089.webp)
6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
89
6.7.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
202D
h
VAR
position_demand_sync_value
INT32
ro
2030
h
VAR
set_position_absolute
INT32
wo
6062
h
VAR
position_demand_value
INT32
ro
6063
h
VAR
position_actual_value*
INT32
ro
6064
h
VAR
position_actual_value
INT32
ro
6065
h
VAR
following_error_window
UINT32
rw
6066
h
VAR
following_error_time_out
UINT16
rw
6067
h
VAR
position_window
UINT32
rw
6068
h
VAR
position_window_time
UINT16
rw
607B
h
ARRAY
position_range_limit
INT32
rw
60FA
h
VAR
control_effort
INT32
ro
60FB
h
RECORD
position_control_parameter_set
rw
60FC
h
VAR
position_demand_value*
INT32
ro
6510
h
_20
h
VAR
position_range_limit_enable
UINT16
rw
6510
h
_22
h
VAR
position_error_switch_off_limit
UINT32
rw
Affected objects from other chapters
Index
Object
Name
Type
Chapter
607A
h
VAR
target_position
INT32
8.3 Positioning operating mode
607C
h
VAR
home_offset
INT32
8.2 Homing
607D
h
VAR
software_position_limit
INT32
8.3 Positioning operating mode
607E
h
VAR
polarity
UINT8
6.3 Conversion factors
6093
h
VAR
position_factor
UINT32
6.3 Conversion factors
6094
h
ARRAY
velocity_encoder_factor
UINT32
6.3 Conversion factors
6096
h
ARRAY
acceleration_factor
UINT32
6.3 Conversion factors
6040
h
VAR
controlword
INT16
7.1.3 Controlword (control word)
6041
h
VAR
statusword
UINT16
7.1.5 Statuswords (status word)
Содержание CMMP Series