2
CANopen [X4]
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
19
2.4.5
Setting the physical units (factor group)
In order for a fieldbus master to exchange position, speed and acceleration data in physical units
(e.g. mm, mm/s, mm/s
2
) with the motor controller, it must be parameterised via the factor group
Parameterisation can be carried out via FCT or the fieldbus.
2.5
Configuration CANopen master
You can use an EDS file to configure the CANopen master.
The EDS file is included on the CD-ROM supplied with the motor controller.
You will find the most current version under
www.festo.com/sp
EDS files
Description
CMMP-AS-...-M3.eds
Motor controller CMMP-AS-...-
M3
with protocol “CiA402 (DS 402)”
CMMP-AS-...-M0.eds
Motor controller CMMP-AS-...-
M0
with protocol “CiA402 (DS 402)”
Tab. 2.11