Festo — CMMP-AS-...-M0 — 2022-07c
Assembly and installation
21
4
Assembly and installation
4.1
Mounting/removal
The safety circuit is integrated in the motor controller CMMP-AS-…-M0 and cannot be removed.
Information on installing the CMMP-AS-...-M0 can be found in the hardware documentation, GDCP-
CMMP-M0-HW-...
Tab. 2 Documentation for the motor controller CMMP-AS-...-M0.
4.2
Electrical installation
4.2.1
Safety instructions
The requirements of EN 60204-1 must be fulfilled for the installation.
WARNING
Danger of electric shock from voltage sources without protective measures.
• Use only PELV circuits in accordance with EN 60204-1 (protective extra-low voltage, PELV) for the
electrical logic power supply. Also take into account the general requirements for PELV circuits in
accordance with EN 60204-1.
• Only use power sources that guarantee reliable electrical isolation of the operating voltage from the
mains in accordance with EN 60204-1.
Protection from electric shock (protection from direct and indirect contact) in accordance with EN
60204-1 (Electrical equipment of machines, General requirements) is guaranteed with the use of PELV
circuits. A 24 V fixed power supply used in the system must satisfy the requirements of EN 60204-1 for
DC power supplies (behaviour during power interruptions, etc.).
The cable is connected to a plug, which makes it easier to replace the motor controller.
Make sure that bridges or the like cannot be inserted parallel to the safety wiring. For example, use
the maximum wire cross section of 1.5 mm
2
or appropriate wire end sleeves with insulating collars.
Use twin wire end sleeves for looping cables between adjacent devices.
ESD protection
Damage may be caused to the device or to other system parts at unassigned plugs as a result of
ESD (electrostatic discharge). Earth the system parts prior to installation and use appropriate ESD
equipment (e.g. shoes, earthing straps etc.).
4.2.2
Connection [X40]
The motor controller CMMP-AS-...-M0 has a combined interface for open-loop control and feedback via
the plug [X40] for the integrated safety function.
–
Version on the device: PHOENIX MINICOMBICON MC 1.5/8-GF-3.81 BK
–
Connector (in scope of delivery): PHOENIX MINICOMBICON MC 1.5/8-STF-3.81 BK, connection
according to section
Содержание CMMP-AS M0 Series
Страница 1: ...CMMP AS M0 Motor controller Manual Safety function STO 8179184 2022 07c 8179186 ...
Страница 41: ......