Assembly instructions (Translation: en)
755130
1206NH
†‡
Electric sub-base
CAPC-F1-E-M12
Festo AG & Co. KG
Postfach
D-73726 Esslingen
+49 (0)711 347 0
www.festo.com
1.
Parts list
1a.
CAPC-F1-E-M12
17381d_1
1
Elec. sub-base
2
Moulded seal
(1x)
(1x)
The intended purpose of the
elec. sub-base
1
is the decen-
tralised installation of CTEU
bus nodes and the connection
of devices with an I-port inter-
face.
17381d_11
Not included in scope of
delivery:
3
M4 screws
(4x)
1b.
CAFM-F1-H
17381d_2
4
H-rail
mounting
(1x)
The intended purpose of the
H-rail mounting
4
is the
installation of the elec. sub-
base
1
on a top-hat rail.
2.
Technical data
1)
CAPC-F1-E-M12
Protection class
2)
IP65/IP67 (
Chapter 5)
Storage temperature
[°C]
−
20 … +70
Note
In order to avoid material damage and operating malfunctions.
Observe the permissible tightening torques.
3.
Mounting
1738
1d_4
Remove the sealing plug (A)
from the bus node (B) with,
for example, a screwdriver.
For this use the recesses on
the side (C) of the sealing
plug (A).
1738
1d_1
0
Press the moulded seal
2
together on the sides.
1738
1d_5
Note
In order to ensure that the
moulded seal
2
functions
correctly:
Fit the moulded seal
2
in
the groove (D)
–
without any undulations
–
parallel to the surface (E)
–
undamaged.
1)
Further technical data can be found in the documentation on the CTEU-... bus node.
2)
Protection provided by housing in accordance with IEC/EN 60529.
1738
1d_6
Note
In order to avoid damage to
the pin contacts (F):
Mount the bus node (B)
straight and without the use
of any high force.
Tighten the self-cutting
screws (G).
If it has to be mounted
again, use the available
threads.
4.
Fastening
1738
1d_7
4a.
Using the screws
3
:
The elec. sub-base
1
is
intended to be fastened to the
wall by means of
for example a mounting rail
or mounting plate.
Place the elec. sub-base
1
on a mounting rail (H) for
example (20 mm grid).
Fasten the elec. sub-base
1
with suitable screws
3
and
slot nuts.
1738
1d_8
4b.
Using the H-rail
mounting
4
:
Place the H-rail clip (I) on
the drill hole of the elec.
sub-base
1
.
Tighten the self-cutting
screw (J) with a
T10 screwdriver.
5.
I-port interface
Bush M12
Pin
Allocation
Function
5-pin, A-coded
1 24
V
EL/SEN
(PS) Operating voltage supply
2 24
V
VAL/OUT
(PL) Load
voltage
supply
3 0
V
EL/SEN
(PS)
Operating
voltage
supply
4 C/Q
I-PORT
Data
communication
3)
5 0
V
VAL/OUT
(PL) Load
voltage
supply
Housing FE
Functional
earth
17381d_9
1738
1d_1
3
Note
To comply with protection class
IP65/IP67:
Plug the unused connections
with the enclosed cover
caps (K).
Mount a connecting cable (L) to the elec. sub-base
1
.
6.
Earthing
1738
1d_1
2
Note
Connect the earthing con-
nection (M) with low imped-
ance to the earth potential.
Use suitable cable lugs (N).
Tighten the screw (O) with a T10 screwdriver.
3)
Voltage supply via pin 4 (two-conductor system PHY1) is not permissible.
I
J
0.6 Nm
_
20 %
1
1
3
1
2
3
4
B
1
G
1 Nm
_
10 %
F
M
C
B
A
C
C
2
K
0.1 Nm
_
10 %
L
E
D
H
N
O
1
0.4 Nm
_
20 %
M