3 TECHNICAL SPECIFICATIONS AND FUNCTIONS

Resolution

0.01 mm

Battery

Button-cell 1.5 V

Measuring speed 

≤ 1.5 m/s

Operating temperature

0 ~ +40°C

Relative humidity

< 80 %

Storage temperature

-10°C

It is possible to reset the measurement in any position making it easy to perform
incremental measurements
It is possible to switch the measurement from millimetres to inches at any time during

measuring.
It is possible to manually turn off the caliper or wait for it to switch off automatically after

4 minutes of inactivity.

4 OPERATING INSTRUCTIONS

Dry the protective sticker area and clean the measuring surfaces

Loosen the locking screw and move the slider to make sure that the LCD screen and

the buttons are working properly.

Turn on the caliper by pressing the ON/OFF button

Press the measurement unit change button, if necessary, to select the desired unit of

measurement.

Bring the two measuring faces gently into contact with each other and press the ZERO

button to proceed with the resetting of the instrument.

Move the two measuring faces towards the object to be measured and press gently

against it. Display the measurement on the screen.

Press the ON/OFF button to turn off the instrument.

Figure 2 – Types of measurement

fervi.com

Содержание C033/150

Страница 1: ...OPERATION AND MAINTENANCE MANUAL Digital caliper Art C033 150 C033 200 C033 300 TRANSLATION OF THE ORIGINAL INSTRUCTIONS f e r v i c o m ...

Страница 2: ...ssess all the necessary information and instruction and should be given adequate training in relation to safety regarding a Conditions of use for the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the instrument complies with the specifications and technical instructions described in the Manual on the date of its issuance shown in this p...

Страница 3: ...d 4 Do not allow any part of the digital caliper to come into contact with electric current e g impact with an electric pen to prevent damage to the integrated circuits 5 Remove the battery from its compartment when the caliper is not in use for a long period of time 2 DESCRIPTION OF THE INSTRUMENT Figure 1 Overview 1 Scale measurement face 8 Protective sticker 2 Internal measurement faces 9 Depth...

Страница 4: ... of inactivity 4 OPERATING INSTRUCTIONS Dry the protective sticker area and clean the measuring surfaces Loosen the locking screw and move the slider to make sure that the LCD screen and the buttons are working properly Turn on the caliper by pressing the ON OFF button Press the measurement unit change button if necessary to select the desired unit of measurement Bring the two measuring faces gent...

Страница 5: ...h identical specifications The positive pole of the battery should be facing outward After replacing the battery it will be necessary to reset the instrument 6 TROUBLESHOOTING Problem Possible causes Solutions Flashing digits Low voltage Replace the battery Display off Low voltage Poor contact of the battery Replace the battery Adjust the position of the battery and clean the housing Fixed digits ...

Отзывы: