![Fervi 786 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/fervi/786/786_operation-and-maintenance-manual_2282370009.webp)
HARDWARE
Page 9 of 16
4 COMMISSIONING
Before it is possible to use the pneumatic gun
Art. 0786,
put a few drops of lubricating oil
(without resin acid) into the air inlet nozzle (Figure 8 ref. C), remove the air inlet cap, then
screw the nozzle supplied:
3/4" NPT Male Quick-Release Coupling
1. Check the flexible air supply hose. If it is damaged, broken, torn or deformed it must not
be connected to the tool.
2. Check the state of the quick-release couplings (both on the tool and the hose). If signs of
damage are detected, it is broken or excessively corroded, the tool or the flexible hose
cannot be used.
3. The tool must be connected to the air supply source by means of an FRL air conditioning
unit, consisting of a filter, pressure regulator and lubricator, as shown in Figure 4.
The compressed air used must be clean and with the right mix of oil. Adjust the lubricator
in such a way that it applies 3 to 6 drops of oil per minute. Furthermore, the maximum
length of the hose must be a maximum of 6/8 metres.
Figure 4 - Connecting the air supply.
4. Insert the quick coupling of the supply hose into the air inlet nozzle at the bottom of the
handle.
Anti-wear
tube
Tool
Tube
Quick release
connector
Nozzle
Pressure
regulator
Filter
Oiler
Centralised
circuit
fervi.com