5.4 Troubleshooting Procedures
Section 5: Troubleshooting
CV-6SLX User Manual
5-16
0101-8242-0, Rev. C
5.4.2 Troubleshooting Tables
This section contains the following troubleshooting tables:
Table Number and Title
Page No.
Table 5-4 HVPS and FPS Are Powered Up but GUN READY State Not Achieved/Confirmed .............. 5-18
Table 5-5 HVPS Powered Up but HV Does Not Switch On When Commanded To Do So .................. 5-18
Table 5-6 FPS Powered Up but Gun Does Not Switch On When Commanded To Do So ................... 5-19
Each table is organized around a set of operational symptoms that should be easily identifiable to the operator.
For functional descriptions of the HVPS front panel LEDs, see section 5.2. For descriptions of the LEDs on the
FPS, see section 3.3. The Ishikawa diagrams in section 5.3 provide additional information about the faults
covered in many of the troubleshooting tables.
Table 5-1 No Input Power Indicated
Symptoms
•
TCS displays
PSU1_RDY_ALM
( = Power Supply Control Not Ready Timeout Alarm).
•
HVPS Front Panel: No LEDs are lit, and displays are dark.
For additional information about this fault mode, see Ishikawa Diagram #1.
Possible Causes
Procedure
1.
Loss of main line power
1.
Check to see whether input line voltages a HVPS rear panel terminals L1, L2,
and L3 are within specifications for your facility. If so, proceed to next step. If
not, check circuit protection devices (i.e., either circuit breakers or fuses) on
the facility input power circuit to ensure they are not tripped or blown.
2.
Power supply’s front breakers are
tripped.
2.
Reset front breakers and attempt to power up the unit. If breakers trip again,
proceed to next step.
3.
Loose or faulty line power connection 3.
Check for secure connections on main three-phase line power connector on
rear of unit.
4.
Fault condition(s) whose investigation
requires removal of HVPS top cover.
4.
Contact Temescal Field Service.
Содержание Temescal CV-6SLX
Страница 4: ...CV 6SLX User Manual ii 0101 8242 0 Rev C...
Страница 16: ...1 5 TemEBeam Controller EBC Section 1 Introduction to the CV 6SLX CV 6SLX User Manual 0101 8242 0 Rev C 1 4...
Страница 34: ...2 6 Cable Installation Section 2 Installation CV 6SLX User Manual 0101 8242 0 Rev C 2 18...
Страница 90: ...5 5 FPS Fuse Replacement Procedure Section 5 Troubleshooting CV 6SLX User Manual 5 32 0101 8242 0 Rev C...
Страница 92: ...Appendix A Pinout Table for Rear Panel Diagnostic Port J3 CV 6SLX User Manual A 2 0101 8242 0 Rev C...