![Ferroli Optimax HE PLUS C Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ferroli/optimax-he-plus-c/optimax-he-plus-c_instructions-for-installation-use-and-maintenance-manual_2282064004.webp)
OPTIMAX HE PLUS C
4
EN
cod. 3540I885 - 08/2012 (Rev. 00)
1. Instructions
1.1 Introduction
Dear Customer,
thank you for choosing the
OPTIMAX HE PLUS C
, a
FERROLI
wall-mounted boiler of the latest generation, featuring
advanced design and cutting-edge technology.
OPTIMAX HE PLUS C
is a high-efficiency
condensing pre-mix
appliance for heating and hot water production with
extremely low emissions, running on natural gas or LPG.
The boiler consists of an aluminium laminar heat exchanger providing effective condensation of the water vapour con-
tained in the flue gases, permitting extremely high efficiency.
Above the heat exchanger, in the boiler, there is a
pre-mix burner
, with a large ceramic surface, equipped with elec-
tronic ignition and ionization flame control, which achieves extremely low emissions while ensuring high reliability and
long life operation.
The boiler is totally
room sealed
from the installation room: the air needed for combustion is drawn from outside. The
boiler also includes a modulating speed fan, modulating gas valve, pump, expansion vessel, safety valve, flow sensor,
temperature sensors, a safety thermostat and a low water pressure switch.
Thanks to the
microprocessor
control and adjustment system with advanced self-diagnosis, unit operation is for the
most part automatic. The power for heating is automatically governed by the control system.
The display continuously provides information on the unit’s operating status and it is easily possible to obtain additional
information on the sensor temperatures, set-points, etc. or configure them. Any operating problems associated with the
boiler or system is immediately signalled by the display and, if possible, corrected automatically.
1.2 Control panel
fig. 1 - Control panel
Key
1 =
Domestic Hot Water temperature setpoint de-
creasing push button
2 =
Domestic Hot Water temperature setpoint in-
creasing push button
3 =
Central Heating water temperature setpoint de-
creasing push button
4 =
Central Heating water temperature setpoint in-
creasing push button
5 =
Display LCD
6 =
Reset / OTC push button
7 =
Economy-Comfort / On-Off push button
8 =
Domestic Hot Water symbol
9 =
Domestic Hot Water mode operation
11 =
Multi-function indication (Flashing during heat
exchanger protection)
12 =
Economy symbol
13 =
Central Heating mode operation
14 =
Central Heating symbol
15 =
Burner on and actual load indication (Flashing
during flame current supervision)
eco
comfort
reset
8
9
15
13
14
12
11
2
1
4
3
6
7
5
Содержание Optimax HE PLUS C
Страница 1: ...cod 3540I885 08 2012 Rev 00 OPTIMAX HE PLUS C INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE...
Страница 33: ......
Страница 34: ......