30
OPTIMAX HE PLUS 38 C
Cod. 3540I892 - 02/2009 (Rev. 00)
Fault
Possible cause
Cure
F12
DHW sensor fault
Sensor damaged
Check the wiring or replace the sensor
Wiring shorted
Wiring disconnected
F13
Flue sensor fault
Sensor damaged or wiring shorted
Check the wiring or change the sensor
Sensor damaged or wiring broken
Check the wiring or change the
sensor
F14
Flow sensor fault
Sensor damaged or short circuited
Check the wiring or change the sensor
Sensor damaged or wiring broken
Check the wiring or change the sensor
F15
Fan problem
Tachometer signal interrupted, fan
connection
Check the wiring and fan
Fan damaged, debris in fan
Check the fan, clean debris
F34
Supply voltage under 170V.
Electric supply problem
Check the electrical system
F35
Irregular mains frequency
Electric supply problem
Check the electrical system
F37
Incorrect system water pressure
Pressure too low
Fill the system
Sensor damaged
Check the sensor
F39
External probe fault
Sensor damaged or short-circuited
Check the wiring or change the sensor
F42
Flow sensor fault
Sensor damaged
Change the sensor
Содержание Optimax HE Plus 38 C
Страница 37: ......