3.01 Drilling Template (Top Flue Application)
Select suitable mounting position for boiler, using the template mark fl ue outlet and boiler mounting points.
Drill two 10mm holes 70mm deep to accept the wall plugs. Fit standard wall plugs on the left and right side and
the special wall plug in the middle (fi g. 13a). Fix the wall bracket to the wall using standard lock nut (M8) on both
sides. Mount the boiler on the wall bracket and fi x using the special antitheft nut (M8) as described in the fi g. 13a.
Using a core drill cut a 118mm diameter hole for the fl ue
.
1.
CH fl ow
2.
Safety Valve
3.
Domestic hot water outlet
4.
Gas supply
5.
Domestic hot water inlet
6.
CH
return
Fig.
13b
Ø3/4"
Ø1/2"
Ø1/2"
Ø1/2"
Ø1/2"
Ø3/4"
200
Ø118
165 min
65
21 min
5 min
183 min
295.5 min
200 min
932 min
269
110
125 min
280
1 2
3
4
5
6
Fig. 13a