ECONCEPT TECH 35 A
31
EN
cod. 3540I341 - 04/2008 (Rev. 00)
4.6 Wiring diagram
fig. 34 - Wiring diagram
A
Caution
: Before connecting the
room thermostat
or the
remote timer control
, remove the jumper on the
terminal block.
16
Fan
32
Heating circulator
44
Gas valve
72
Room thermostat
82
Detection electrode
95
Diverter valve
114
Water pressure switch
138
External sensor
139
Remote timer control
155
Hot water temperature sensor (optional)
186
Return sensor
188
Ignition electrode
191
Fume temperature sensor
278
Double sensor (h safety)
256
Modulating heating circulator pump signal
72
95
155
114
191
16
186
188
82
T°
T°
278
139
138
256
32
16
44
N
L
230V
50Hz
1 2 3
4 5 6
DBM04A
10kOhm
1.8kOhm