Installation and maintenance manual
pag. 18 / 23
5.1.1.1
List of equ ipment parameters
Parameter description
Code
U.M.
Min
Max
Default Notes
Password (shadow)
PA
0
Function reserved for
specialised technical staff
H2O Set HOT economy cycle
SP1
°C/°F
r3
r4
55.0
H2O Set HOT automatic cycle
SP2
°C/°F
r1
r2
55.0
H2O Set COLD
SP3
°C/°F
10.0
r2
45.0
H2O Set for heat pump stop
SP5
°C/°F
r1
SP2
62.0
(
56
°C for L versions)
H2O Set for the enabling of photovoltaic
supplement
SP6
°C/°F
40.0
100.0
75.0
H2O Set ANTI-FREEZE
SP7
°C/°F
0
40
10
Set point GREEN cycle
SP8
°C/°F
0
100.0
40
Set cold evaporator
SP9
°C/°F
-25.0
25.0
-7.0
Set damaged evaporator
SP10
°C/°F
-50.0
25.0
-25.0
Upper probe calibration
CA1
°C/°F
-25.0
25.0
0.0
Lower probe calibration
CA2
°C/°F
-25.0
25.0
0.0
Evaporator probe calibration
CA3
°C/°F
-25.0
25.0
0.0
Probe type P0
----
0
1
1
0 = PTC
1 = NTC
2 = PT1000
Decimal point P1
----
0
1
1
1 = Decimal point per
Dy(dysprosium)
temperature
Unit of measurement P2
----
0
1
0
0 = °C
1 = °F
Function associated with the evaporator
probe
P4 ----
0 2
2
0 = Disabled
1 = Defrosting start-stop
2 = Defrosting start
Local display data P5
----
0
3
0
0 = Upper probe
1 = Operative set point
2 = Lower probe
3 = Evaporator probe
Remote display data P6
----
0
3
0
0 = Upper probe
1 = Operative set point
2 = Lower probe
3 = Evaporator probe
Display data refresh time specified in
tenths of a second
P8
1/10
sec
0 250
5
Work set hysteresis
r0
°C/°F
0.1
30.0
7.0
Minimum auto cycle set point
r1
°C/°F
10.0
r2
40.0
Maximum auto cycle set point
r2
°C/°F
r1
100.0
70.0
Minimum economy cycle set point
r3
°C/°F
10.0
r4
40.0
Maximum economy cycle set point
r4
°C/°F
r3
100.0
62.0
(
56
°C for L versions)
Work set change block r5
----
0
1
0
1 = It is not possible to
change the set point; it