333
EN
cod. 3541V481 - Rev. 00 - 06/2021
* Restore Factory Values
To restore all the parameters to the factory values, set parameter
b29
to
10
and confirm. Turn the
power off for 10 seconds and then back on.
At this point it is necessary to return parameter
b02
to the correct value, according to the type of
boiler. Parameter
b27
will be automatically set to
5
.
Display Adjustment Menu [DISPLAY]
Here it is possible to set some display pa-
rameters.
[Contrast]
Contrast adjustment.
[Brightness]
Brightness adjustment
[Backlight time]
Display backlight duration.
[Reset]
Restore factory values.
P63
Fan On speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
BLUEHELIX HITECH RRT 18 H
= 160
BLUEHELIX HITECH RRT 28 H
= 160
BLUEHELIX HITECH RRT 34 H
= 140
G30/G31:
BLUEHELIX HITECH RRT 18 H
= 152
BLUEHELIX HITECH RRT 28 H
= 152
BLUEHELIX HITECH RRT 34 H
= 132
P64
Fan maximum speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
BLUEHELIX HITECH RRT 18 H
= 140
BLUEHELIX HITECH RRT 28 H
= 172
BLUEHELIX HITECH RRT 34 H
= 194
G30/G31:
BLUEHELIX HITECH RRT 18 H
= 134
BLUEHELIX HITECH RRT 28 H
= 156
BLUEHELIX HITECH RRT 34 H
= 186
P65
Not implemented
--
1
P66
Valve frequency
0 ÷ 2
1
P67
Installation C10/C11
0 - 1
0
P68
Flue parameter
0 ÷ 10 (modify according to flue table)
0
Index
Description
Range
Default
Содержание 0T4D1AWA
Страница 1: ...INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...
Страница 39: ...334 EN cod 3541V481 Rev 00 06 2021 fig 40 ...
Страница 45: ...340 EN cod 3541V481 Rev 00 06 2021 fig 48 fig 49 fig 50 ...
Страница 53: ...348 EN cod 3541V481 Rev 00 06 2021 4 4 Technical data table ...
Страница 54: ...349 EN cod 3541V481 Rev 00 06 2021 ...
Страница 55: ...350 EN cod 3541V481 Rev 00 06 2021 ...
Страница 56: ...351 EN cod 3541V481 Rev 00 06 2021 ...
Страница 59: ......
Страница 60: ......
Страница 61: ......