08. Troubleshooting
Error
Possible cause
Troubleshooting
POWER LED does not light
Power supply not plugged in or
defective
Check the power supply
The device is switched off
Switch on the device with the
power button. Seriously.
POWER LED flashes quickly
Power button pressed
The power LED flashes quick-
ly when the power button is
pressed on a switched-on de-
vice.
POWER LED flashes slowly
The Verto unit is booting in the
start-up process
Wait approx. 20 seconds for the
boot-up-sequence to finish.
DANTE LED does not light up
(see Power LED)
Mains cable defective or the
wrong type (crossed) is used
Use a different network cable
Verto is booting
Wait approximately 20s until the
boot process is finished
Error in the DANTE network
Check the functioning of the
DANTE network.
DANTE LED is flashing
No connection to the Dante
network
Check the functioning of the
DANTE network.
Device is „slave“, but no “Mas-
ter“ was found on the DANTE
network.
Set a device in the DANTE net-
work to „Master“
Sample rate on the network
has been changed
When changing the sample rate,
the outputs are muted briefly.
MADI coaxial LED lights low Both ports (opto & coax) re-
ceive valid signal
Both signals are valid, but the
optical port is automatically used
for DANTE.
This is a status indication, not
an error.
ADAT Input LED flashes
A sync process has failed
Set all connected ADAT devices
to „Slave“.
ADAT Input LED is lit constantly,
regularly interrupted by flick-
ering
Both devices are „Master“.
Set all connected ADAT devices
to „Slave“.