background image

 

 

10 

ENGLISH 

1

 

Introduction 

In  this  booklet  you  will  find  installation  instructions  for  your 

EnergyHub  XL  Single.  Please  read  the  instructions  carefully  to 

prevent unnecessary errors. 

1.1

 

Included items 

Article 

Amount 

Wall mounted Cabinet  

EnergyHub XL 21/28 kW 

AC connector 

DC nanogrid connector 

Current transformer (CT) kit 160A  

CT adapter 

Capacitor box 

M6x12 Screw 

M6 cage nut 

Thumb screw 

Installation manual 

Commissioning guide 

Installer verification 

Warranty booklet 

 

1.2

 

Warnings and reservations 

RECOMMENDATION! 

Read through the manual before installation. 

RECOMMENDATION!

  Only  use  this  product  according  to  the 

instructions supplied to avoid any danger.  

WARNING!

 

EnergyHub  XL  Single  may  not  be  opened  by 

unauthorized personnel. Contact the reseller if you need service.  

WARNING!

 

The  electrical  installations  shall  be  conducted  by 

authorized  personnel  and  in  accordance  with  local  and  national 

electrical standards and safety measures.    

WARNING!

 You are not allowed to connect units to the DC nanogrid 

when it is energized. 

WARNING!

 

Risk of electrical shock/arc if the product is not used 

according to the instructions in the manual.  

WARNING!

 Do not use  the product if you suspect the product is 

damaged. Let it be inspected by qualified personnel before use.  

WARNING!

 

Do  not  use  the  product  if  the  housing  has  been 

tampered  with  or  not  intact,  for  example  during  repair,  do  not 

touch exposed parts.  

NOTE!

  The  warranty  does  not  apply  if  the  product  has  been 

modified, tampered with, or not installed in accordance with this 

manual. 

1.3

 

Explanation of safety notices 

 

 

 

 

1.4

 

Dimensions 

All dimensions are in mm if nothing else is specified.  

 

 

 

 

 

 

 

The flash symbol in an equilateral triangle warns 
of dangerous voltage.

 

 

The exclamation mark in an equilateral triangle is 
intended to warn the user that negligence of this 
information can be life threatening!

 

 

 

 

The  exclamation  mark  in  a  circle  is  intended  to 
inform  the  user  that  neglect  of  this  information 

may  be  associated  with  bodily  injury  and  /  or 

damage to the product. 

 

 

Содержание EnergyHub XL Single 21 kW

Страница 1: ...Installation manual EnergyHub XL Single 21 28 kW Rev A01...

Страница 2: ......

Страница 3: ...ion 10 1 1 Included items 10 1 2 Warnings and reservations 10 1 3 Explanation of safety notices 10 1 4 Dimensions 10 1 5 Components 11 1 6 Connections 11 2 Installation 12 2 1 Required tools 12 2 2 Pl...

Страница 4: ...elektrisk standard och s kerhetsf reskrifter VARNING Du f r ej ansluta enheter till liksp nningsn tet n r det r sp nningssatt VARNING Risk f r elektrisk st t och ljusb ge om produkten inte hanteras i...

Страница 5: ...CT adapter 5 Kabelgenomf ringar 1 6 Anslutningar EnergyHub XL 1 Str mtransformator CT 2 AUX rel anv nds EJ 3 D SUB CAN anv nds EJ 4 terst llningsknapp 5 Ethernet ETH anv nds EJ 6 Kabeling ng f r disp...

Страница 6: ...placeras i ett sk p eller liknande inneslutning m ste mekanisk ventilation finnas f r att s kerst lla tillr cklig v rmeavledning Omgivningstemperaturen f r inte understiga 0 C och inte verstiga 45 C...

Страница 7: ...gen F stanordning m ste kunna b r minst 60 kg 2 3 Montera EnergyHub XL modul 1 Placera de sex medf ljande burmuttrarna enligt figur nedan 2 N r du lyfter in EnergyHub XL modulen se till att ha AC och...

Страница 8: ...h m tning datainsamling NOTERA Kabeln f r liksp nningsn tet beh ver inte ha en M ledare om det inte ska vara en Powershare installation Ett sammankopplat liksp nningsn t mellan EnergyHubar Skala av 14...

Страница 9: ...mellan paren r d vit svart bl gr n gul Alla par b r visa liknande motst nd vid korrekt installation 4 F st kontakthuset Se till att dragavlastningen i kontakthuset f ster runt CT kabelns isolering 5 A...

Страница 10: ...anslutningen IPv4 adress samt fungerande DNS server och NTP server tilldelas med hj lp av DHCP Utg ende trafik till internet m ste fungera felfritt Information om specifika portar och mer detaljer kan...

Страница 11: ...9...

Страница 12: ...national electrical standards and safety measures WARNING You are not allowed to connect units to the DC nanogrid when it is energized WARNING Risk of electrical shock arc if the product is not used a...

Страница 13: ...4 CT adapter 5 Cable glands 1 6 Connections EnergyHub XL 1 Current transformer CT 2 AUX relay NOT used 3 D SUB CAN NOT used 4 Reset button 5 Ethernet connection NOT used 6 Cable connection for Displa...

Страница 14: ...ilated if the EnergyHub XL Single is placed in a sealed area then forced ventilation must be provided to ensure adequate heat dissipation Ambient temperatures must not fall below 0 C and not exceed 45...

Страница 15: ...the mounting surface can carry a weight up to 60 kg 2 3 Mount EnergyHub XL module 1 Insert the six cage nuts in the following positions 2 Lift in the EnergyHub XL make sure that the AC and DC connecti...

Страница 16: ...nt equalization ACE and measuring data collection NOTE The DC nanogrid cable does not require an M conductor unless you are installing a Powershare system a DC nanogrid with two or more EnergyHub syst...

Страница 17: ...proper connection and eventual cable extension measure the resistance between the pairs All pairs red white black blue green yellow should show similar resistance 4 Attach the contact housing make su...

Страница 18: ...Internet connection IPv4 address as well as functioning DNS server and NTP server are assigned using DHCP Outgoing traffic to the internet must work properly Information on specific ports and more det...

Страница 19: ...17...

Страница 20: ...Electricity Reinvented...

Отзывы: