3
3.DAILY INSPECTION
Daily inspection is effective to find the malfunction or fault on the lift table.
Before operation, check the lift table according to the following points.
CAUTION!
Do not use the lift table if any
malfunction or fault is found.
◇
Check all the terms of WARNING and CAUTION.
◇
Check scratches, bending or crack on the lift table.
◇
Check smooth movement of the table.
◇
Check if there is any hydraulic oil leakage.
◇
Check the vertical creep of the table.
◇
Check if all the bolts and nuts are firmly tightened.
4.OPERATING THE LIFT TABLE
■
LOADING
The maximum capacity of the lift table is 1000kg. Load should be
distributed on the lift table equably.
■
Lifting the Table
CAUTION!
Do not overload the lift table.
Ensure the balance of loading. Do not load
partially or concentrically.
◇
Screw and loose emergency stop switch.
◇
Push the UP button and power pack starts to work to lift the load.
◇
Loose the UP button and power pack stops working.
■
Lowering the Table
WARNING!
Do not put foot or hand in
scissors mechanism.