1. General instructions

• 

Carefully read the instructions contained in this instruction 

booklet.

• 

After hot water tank installation, inform the user regarding 

its operation and give him this manual, which is an integral 

and essential part of the ECOUNIT F and must be kept with 

care for future reference.

• 

Installation and maintenance must be carried out by profes-

sionally qualified personnel, according to current regulations 

and the manufacturer's instructions. Do not carry out any 

operation on the sealed control parts.

• 

Incorrect installation or inadequate maintenance can result 

in damage or injury. The Manufacturer declines any liability 

for damage due to errors in installation and use or failure to 

follow the instructions.

• 

Before carrying out any cleaning or maintenance operation, 

disconnect the unit from the electrical power supply using the 

system switch and/or the special cut-off devices.

• 

In case of a fault and/or poor operation, deactivate the unit 

and do not try to repair it or directly intervene. Contact pro-

fessionally qualified personnel. Any repair/replacement of 

the products must only be carried out by qualified personnel 

using genuine parts. Failure to comply with the above can 

compromise the safety of the unit.

• 

This unit must only be used for its intended purpose. Any 

other use is deemed improper and therefore hazardous.

• 

The packing materials are potentially hazardous and must 

not be left within the reach of children.

• 

The unit must not be used by people (including children) with 

limited physical, sensory or mental abilities or without expe-

rience and knowledge of it, unless instructed or supervised 

in its use by someone responsible for their safety.

• 

The unit and its accessories must be appropriately disposed 

of, in compliance with the current regulations.

•  The images given in this manual are a simplified represen

-

tation of the ECOUNIT F. In this representation there may 

be  slight  and  insignificant  differences  with  respect  to  the 

ECOUNIT F supplied.

2. Introduction

ECOUNIT F is a vertical hot water storage tank with single coil (vers. 1C) or with double coil (vers. 2C).
This unit is designed for heating domestic hot water to a temperature below boiling point at atmospheric pressure and must 

be connected to an energy source and a DHW system, compatibly with its performance characteristics and power.

PLACE OF INSTALLATION

The place of installation must be protected against frost.
The hot water storage tank must be placed in the immediate vicinity of the heat generator, to avoid pointless heat loss. Suitably 

insulate the feed pipes.

PLUMBING CONNECTIONS

Carry out the relevant connections according to the cover diagram and the symbols given on the unit.
It is advisable to install the unit near the main hot water drawing point, in order to avoid heat loss along the pipes, and possibly 

near a drain to facilitate any emptying operations.
The unit is arranged for connection to a recirculation pipe (

ref. 20

 in fig. 5 and fig. 6): this pipe must be insulated. For recircula

-

tion, it is necessary to install a pump equipped with an operation timer or a minimum contact thermostat, to obtain its activation 

on cooling of the recirculation water.

If the union is not used, fit a suitable plug.

A relief valve (

ref. 11

 in fig. 5 and fig. 6) with setting equal to or greater than the max. DHW pressure given in the 

technical 

data tables

 on pagina 26 must be installed on the cold water feed pipe upstream of the hot water tank.

The connection pipe between the hot water tank and relief valve must absolutely not be shut off, as damage to the hot water 

tank could occur due to overpressure.

  The relief valve outlet must be connected to a funnel or collection pipe to prevent water spurting onto the floor in case 

of overpressure in the hot water tank circuit. Otherwise, if the discharge valve cuts in and floods the room, the boiler 

manufacturer cannot be held liable.

Slight dripping from the relief valve is normal in the heating phase; therefore it is advisable to connect it to a drain with trap.
In case of a mains pressure near the valve setting values, a suitable pressure reducer (

ref. 15

 in fig. 5 and fig. 6) must be fitted 

as far away as possible from the unit.

DHW expansion tank

The DHW expansion vessel must be sized according to the capacity of the hot water tank and the cold water pressure.
If the system has a pressure reducer, for the reason described above, and/or a check valve, it is necessary to install an expan-

sion tank (

ref. 14

 in fig. 5 and fig. 6) having a capacity not less than 5% of the hot water tank nominal capacity.

Do not install a check valve between the relief valve and the expansion tank. In general, to safeguard the unit and the system, 

it is advisable to install the expansion tank with the characteristics defined above.

Fill the special expansion tank diaphragm chamber according to the manufacturer's instructions.

Содержание ECOUNIT 2C Series

Страница 1: ...ECOUNIT F 1C 2C INSTRUZIONI PER USO INSTALLAZIONE E MANUTENZIONE INSTRUCCIONES DE USO INSTALACIÓN Y MANTENIMIENTO USE INSTALLATION AND MAINTENANCE INSTRUCTIONS Cod 30902340 Rev 03 09 2015 30902340 ...

Страница 2: ...e d uso 4 4 Manutenzione e pulizia 5 5 Dati Tecnici 5 1 Advertencias generales 13 2 Presentación 13 3 Normas de uso 14 4 Mantenimiento y limpieza 15 5 Datos técnicos 15 1 General instructions 23 2 Introduction 23 3 Operating instructions 24 4 Maintenance and cleaning 25 5 Technical Data 25 ...

Страница 3: ...cteristics and power PLACE OF INSTALLATION The place of installation must be protected against frost The hot water storage tank must be placed in the immediate vicinity of the heat generator to avoid pointless heat loss Suitably insulate the feed pipes PLUMBING CONNECTIONS Carry out the relevant connections according to the cover diagram and the symbols given on the unit It is advisable to install...

Страница 4: ...or 1 5 kW heating element is required Run the end of the cable from the cable gland to the electrical part Connect the wires to the terminals of the thermostat C Reassemble everything Make sure the thermostat is properly applied to the heating element The thermostat temperature adjustment range is from 15 C to 75 C The thermostat has a safety device which intervenes if the temperature exceeds 93 C...

Страница 5: ...ry Refill the unit according to the startup instructions and check its tightness ANODE CHECK The unit is protected against corrosion by a vitreous enamel coating of the inner surface and the exchange coil The hot water tank also has an anticorrosion magnesium anode to protect against the effect of eddy currents which could damage it the duration depends on operation and the quality of the water Th...

Страница 6: ...OUNIT F 150 1C 500 1325 1216 1088 988 888 336 236 126 400 326 ECOUNIT F 200 1C 540 1453 1344 1084 984 884 334 234 124 440 324 ECOUNIT F 300 1C 620 1535 1431 1161 1061 961 361 261 131 520 351 ECOUNIT F 400 1C 750 1469 1326 985 885 785 441 341 155 650 418 ECOUNIT F 500 1C 750 1769 1626 1261 1161 1061 441 341 155 650 418 Plumbing connections Model DHW connections Coil connections Recirculation connec...

Страница 7: ... 2C 540 1453 1344 1234 1134 1034 934 834 734 234 124 324 440 324 ECOUNIT F 300 2C 620 1535 1431 1311 1211 1111 961 861 761 261 131 351 520 351 ECOUNIT F 400 2C 750 1469 1326 1174 1074 974 852 752 661 391 291 155 650 418 ECOUNIT F 500 2C 750 1769 1626 1474 1374 1274 1152 1052 898 398 298 155 650 418 Plumbing connections Model DHW connections Upper coil connections Lower coil connections Recirculati...

Страница 8: ...obe 6 Boiler outlet 7 Cold water inlet 11 Hydraulic safety valve not supplied 12 Emptying cock not supplied 13 Discharge pipe not supplied 14 Expansion tank not supplied 15 Pressure reducer not supplied 16 Non return valve optional not supplied 17 Shutoff valve optional not supplied 18 Pump optional not supplied 19 Boiler not supplied 20 Recirculation piping optional not supplied ...

Страница 9: ...e 9 Solar inlet 10 Solar outlet 11 Hydraulic safety valve not supplied 12 Emptying cock not supplied 13 Discharge pipe not supplied 14 Expansion tank not supplied 15 Pressure reducer not supplied 16 Non return valve optional not supplied 17 Shutoff valve optional not supplied 18 Pump optional not supplied 19 Boiler not supplied 20 Recirculation piping optional not supplied 21 Hydro assembly 12 not...

Страница 10: ...IT F 300 2C ECOUNIT F 400 2C ECOUNIT F 500 2C Capacity litres 178 275 385 478 UPPER COIL Exchanged power t 35 K kW 12 5 18 29 6 29 6 DHW flow rate t 35 K litres h 306 444 726 726 DHW flow rate t 50 K litres h 216 310 510 510 Preparation time t 35 K min 39 41 33 41 Preparation time t 50 K min 56 58 47 59 Coil exchange surface m2 0 5 0 72 1 19 1 19 Coil length m 6 38 9 17 11 43 11 43 Coil pressure l...

Страница 11: ...150 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 130 EN FERROLI 92 ECOUNIT F 200 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 180 EN FERROLI 92 ECOUNIT F 200 2C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 178 EN FERROLI 112 ECOUNIT F 300 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 277 EN FERROLI 112 ECOUNIT F 300 2C FERROLI S p...

Страница 12: ...FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 385 EN FERROLI 143 ECOUNIT F 500 1C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 480 EN FERROLI 143 ECOUNIT F 500 2C FERROLI S p A via Ritonda 78 A 37047 SAN BONIFACIO VR Italy 478 EN FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...

Отзывы: