5
(6) BATTLE SHORT ON.
(7) Output Terminals and Slave Receptacle. The output
terminal board and ground terminal are located on the generator
set skid base, just below the control box assembly. A hinged
cover (16, Figure 1-2) allows access to the three load terminal
and single ground terminal. An insulated wrench, used for
connecting wires to terminals, is secured to the rear of the
hinged cover. A filter mounted to the back of the load
terminals prevents Electro-Magnetic Interference (EMI). The
generator’s 24VDC slave receptacle is mounted to the skid base,
to the right of the output terminals.
(8) Engine/Generator Assembly. The engine/generator
assembly (Figure 1-3) consists of a single-cylinder engine (14),
permanent magnet generator (5), and associated electrical, fuel
and oil components, The engine/generator assembly is mounted to
the skid base (8) with vibration mounts (7) to prevent engine
vibration from affecting the operation of the generator set
components. A fuel drain plug (9) and oil drain plug (10) allow
maintenance to drain engine fluids.
WARNING
Exposed fuel and fuel vapor can ignite or explode, resulting
in possible serious injury or death.
WARNING
Electrocution Hazard
Electrical high voltage cannot be seen but it can kill you,
render you unconscious, or severely burn you. Failure to
observe safety precautions may result in serious injury or
death.
Содержание MEP-831A
Страница 7: ...7...
Страница 8: ...8...
Страница 9: ...9...
Страница 14: ...14...
Страница 15: ...15...
Страница 16: ...16...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 29: ...29...
Страница 32: ...32 Table 2 2...
Страница 33: ...33 Table 2 2...