FEATURES

ƒ

  

Fibre Optic.

o Connector: FC/PC.

o Fibre: Mono Mode.
o Maximum Distance: 5km.

ƒ

  

Video.

o Connector: BNC 75-5.
o Video Signal:1Vpp (75 Ohm).

o Noise Signal Ratio (NSR) >67dB.

o Bandwidth: 5Hz – 10MHz.

ƒ

  

Data.

o Connector: 2.5mm, 4 terminal grid.

o Protocol: RS-485.

o Speed:< 300Kbps.

o Operating Mode: full duplex.

ƒ

  

Audio.

o Connector: 2.5mm, 4 terminal grid.
o Input/Output Impedance: 600 Ohm.
o Input/Output Level: 0dBm.

o Frequency Response: 10Hz – 20 KHz.

o Noise Signal Ratio: 80dB.

ƒ

  

Contact.

o Connector: 2.5mm, 4 terminal grid.

o Input Contact:  0/5V opto-coupled.  Contact Opening/Closing Transmission.

o Output Contact:   0.1A relay

ƒ

  

Environmental  Requirements.

o Operating Temperature: -20º C ~ +85º C

o Relative Humidity: 10% ~ 95%

Содержание RX 1001

Страница 1: ...As part of its policy of constant improvement FERMAX ELECTRONICA S A E reserves the right to modify the content of this document and the characteristics of the products referred to in it at any time...

Страница 2: ...Page3 Introduction 4 Features 6 Installation 7 Transmitter TX 1010 8 Receptor RX 1001 9 Diagrams 10 1 Panel Bus 10 2 Decoder Bus 12 3 Central Unit Network 14 INSTALLATIONMANUAL Table of Contents...

Страница 3: ...Page4...

Страница 4: ...or that common in the case of large distances providing isolation against electro static charges produced by storms It is comprised of a pair of elements Transmitter TX installed on the entry panel si...

Страница 5: ...l RS 485 o Speed 300Kbps o Operating Mode full duplex Audio o Connector 2 5mm 4 terminal grid o Input Output Impedance 600 Ohm o Input Output Level 0dBm o Frequency Response 10Hz 20 KHz o Noise Signal...

Страница 6: ...r its installation It can also be placed on a platform which supports a weight of 5 Kg For both devices o Set up data audio and contact conections on terminal grids D0 D1 and D3 respectively o Connect...

Страница 7: ...een led should be on o D1 data The green led should flash when it transmits or receives data PWR POWER 5 8VDC 3A SYN V1 V2 V3 V4 D3 D4 D5 D0 D1 D2 FTRX PORT D0 1 2 D1 1 2 1 2 D2 3 4 1 2 D3 3 4 D0 1 2...

Страница 8: ...en led should be on o D1 data The green led should flash when it transmits or receives data PWR POWER 5 8VDC 3A SYN V1 V2 V3 V4 D3 D4 D5 D0 D1 D2 FTRX PORT D0 1 2 D1 1 2 1 2 D2 3 4 1 2 D3 3 4 D0 1 2 D...

Страница 9: ...ERST RKER CT V M 18 PAN TILT JP4 JP1 CN1 Cp1 1 2 3 6 Cp2 CN4 F U L Cp1 L 1 N Aliment P Supply 12 Vac Vdc Aliment P Supply 18 Vdc TEST ENTRADA INPUT ARRIV E EINTRITT CN1 ARRIBA UP HAUT OBEN SALIDA OUTP...

Страница 10: ...2405 UNIDAD CENTRAL MDS MDS CENTRAL UNIT DECODERS D2 D1 M V G 12 Vdc D0 1 2 D1 1 2 1 2 D2 3 4 1 2 D3 3 4 D0 1 2 D1 1 2 DATA RX STAIRS LIGHT RELAY RELE LUZ DE ESCALERA REF 2013 8 1 V 3 4 No C Nc LE Ma...

Страница 11: ...dc B 2 6 FXL PANEL 0 2 SB SA CT 6 V M A B G A 12Vdc REF 2405 UNIDAD CENTRAL MDS MDS CENTRAL UNIT DECODERS D2 D1 M V G 18 Vdc 12 Vdc TELEFONOS D2 BUS D1 6 2 PGM 1 2 1 1 6 4 3 2 4 23 3 D1 BUS 2 6 D2 3 5...

Страница 12: ...23 1 6 D22 D1 4 Ref 5918 M3 M2 M4 2 TELEFONOS REF 2425 M5 6 2D2 5 BUS PGM 1 BUS D1 V 643 8 6 7 3 2 4 1 4 6 2 3 6 1 2 43 1 4 6 2 3 M7 M6 DECODER 8 Ref 2425 1 F2 F1 M V 4 3 2 1 CT 6 CN1 F2 F1 V M M8 M8...

Страница 13: ...SW2 ON ON 5 8 Vdc 18 Vdc 12 Vdc B 2 6 FXL PANEL 0 2 SB SA CT 6 V M A B G A 12Vdc REF 2405 UNIDAD CENTRAL MDS MDS CENTRAL UNIT DECODERS D2 D1 M V G D0 1 2 D1 1 2 1 2 D2 3 4 1 2 D3 3 4 D0 1 2 D1 1 2 DAT...

Страница 14: ...2 3 4 1 2 D3 3 4 D0 1 2 D1 1 2 DATA RX 3B RED DE CENTRALES CENTRAL UNITS NETWORK B 2 6 FXL PANEL 0 2 SB SA CT 6 V M A B G A 12Vdc REF 2405 UNIDAD CENTRAL MDS MDS CENTRAL UNIT DECODERS D2 D1 M V G mall...

Страница 15: ...Page 16...

Страница 16: ...Page 17...

Страница 17: ...www fermax com...