background image

 

Fermax PBX DP

 

analogue door phone panel 

 

Fermax PBX EXP 

Fermax PBX KEY 

Fermax PBX CAM 

Fermax PBX EA 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User and installation guide  

 

Содержание PBX CAM

Страница 1: ...Fermax PBX DP analogue door phone panel Fermax PBX EXP Fermax PBX KEY Fermax PBX CAM Fermax PBX EA User and installation guide...

Страница 2: ......

Страница 3: ...can be expanded by Fermax PBX CAM a module with IP colour camera optionally there can be an add on speaker module with an amplifier Fermax PBX EA which is used for very noisy areas The Fermax New Cit...

Страница 4: ...F THE DOOR PHONE PANEL 18 1 4 1 Surface mounting 18 1 4 2 Flush mounting 18 2 DOOR PHONE NUDV FERMAX PBX DP OPERATION 20 2 1 SIGNALING OVERVIEW 20 2 2 VISITOR AT DOOR 20 2 2 1 Guard without Keyboard 2...

Страница 5: ...4 8 OVERVIEW OF PARAMETERS 34 4 9 LIST OF PRESETTING PARAMETERS 36 5 TECHNICAL PARAMETERS 37 5 1 ELECTRICAL PARAMETERS 37 5 2 MECHANICAL DIMENSIONS 37 6 TABLE FOR EASY PROGRAMMING 38...

Страница 6: ...plated contacts Pushbuttons are manufactured in zamak and a natural chromed finish Card slot lighting by means of low consumption max duration LEDs Card slot lighting can be switched off to be less a...

Страница 7: ...mm 6 294mm 7 341mm 8 389mm 9 436mm group of letters defines basic HW features of panel A audio panel C audio panel with a camera P panel with pushbuttons V panel with a window W panel with two windows...

Страница 8: ...for example the protective roofing Fermax PBX DP panels can be equipped with an additional time switch called TimeRelay It is used for an expansion of the number of switches It is programmable Based...

Страница 9: ...he wireless DECT phone to the other wireless DECT phone e g DTMF transmission is required when you need to use the DTMF command for opening the door DistyBox has got its own power supply it works as a...

Страница 10: ...2 pushbuttons and two pushbuttons with a possibility of expansion by additional 8 pushbuttons i e each basic panel allows connection of up to 10 pushbuttons with no further accessories of Fermax PBX D...

Страница 11: ...ce password is xxxx 0000 This way you can enter the programming mode If the password is invalid then you have the choice of using the service jumper When you call the door phone you are able to enter...

Страница 12: ...e middle position During the voice connection please speak softly and start turning the TRH trimmer to the left side until the other party on the phone side inside the building starts hearing you well...

Страница 13: ...normally closed and COM common terminal of the relay 13 Grounding connector GND it is used for antistatic protection especially for installation at places with marble floor or if the plastering with p...

Страница 14: ...f the manual It means the basic panel with two pushbuttons is being used These two pushbuttons are used pernamently on the main PCB board In the table please deduct 1 from the number of the pushbutton...

Страница 15: ...ermax logo When bottom opening please cover with the grey round plastic cover Both covers incl the screws are part of delivery as accessories 2 Loudspeaker 3 Pushbuttons these two pushbuttons are firm...

Страница 16: ...he basic module Fermax PBX DP and the second one is used for connection of the following module For interconnection please use cable Fermax PBX CC5 Besides connectors 5 you can also find on the expans...

Страница 17: ...ad module any other module The keypad module can be only connected to the second position i e directly to the basic module or to the third position to the output of the first Fermax PBX EXP module Att...

Страница 18: ...mounted installation boxes are refered to as MKxx or simply flush mount installation boxes When using the nearly square flush mount installation box MK1 please pay attention on the correct orientatio...

Страница 19: ...t warms up the electronics during winter when temperatures drop below 20 C most components have got guaranteed parameters for temperatures up to 20 C Secondly if you use the heating of the main PCB bo...

Страница 20: ...ut Call glows Notice about call end 1275 glows Entry to programming from phone 850 glows Programming from phone mod 850 glows Parameter confirmation glows Entry to programming from PC 850 glows Progra...

Страница 21: ...f the visitor at door presses buttons in such combination that meet the preprogrammed code parameters 32 34 and the time among presses is not bigger than the set point parameter 53 then the guard will...

Страница 22: ...t door The code choice can close the switch parameter 35 if set to m 1 or m 5 modes change over the Day Night modes parameters 45 46 and hang up parameter 43 The guard in 10 seconds before call end pa...

Страница 23: ...he guard will come back to this state always after time expiration 5 seconds even you started to program anything When programming two types of parameters will occur Partly they are parameters with fi...

Страница 24: ...ine the guard with PC by KAB cable if PC serial port absent the USB COM reduction is to be used The guard will answer and LED light on the front panel will light Run the Nset program the guard will re...

Страница 25: ...to 16 digits we want to store To store other choice flags the assignment given in table is used The numbers stored in parameter 2 are the number of the second group or numbers of Night mode Neither ba...

Страница 26: ...r keyboard 2 to 6 digits Total 6 passwords they are controlled by Day Night the combination is entered either by guard buttons first 10 buttons or from attached keyboard after pressing of key symbol T...

Страница 27: ...o control the switch during incoming call To prohibit the control during incoming call is important e g when using switch 2 in mode 1 for control of garage gate opening when the electronics opens the...

Страница 28: ...rameters 35 8 84 Parameter Value Meaning Basic 44 xxxx service password 0000 xxxx service password for entry to programming List of related parameters 8 84 Parameter Value Meaning Basic 45 dd command...

Страница 29: ...er corresponds to button number with respect to Day Night switchover ATTENTION This parameter setting will sharply influence keyboard function List of related parameters 1 2 47 48 53 8 84 This paramet...

Страница 30: ...itch closing if time between two next presses is bigger than w time the code is not evaluated correctly dialing dialing the same as of phone if time after the last pressed button is bigger than w time...

Страница 31: ...f related parameters 47 8 85 Parameter Value Meaning Basic 57 t DTMF tone duration tone choice 5 100ms 58 m gap duration among DTMF tones 5 100ms 59 f Flash duration 1 100ms 50 p pause duration interd...

Страница 32: ...3 84 basic setting only for parameters 4x only 4 85 basic setting only for parameters 5x only 5 The parameters 81 and 82 will execute deleting of all numbers stored in memories for buttons The parame...

Страница 33: ...tion This parameter does not basically affect the correct function of guard Parametr Value Description Basic 6 z Switching off acoustic signalization 3 In default is status of Door phone signalling ac...

Страница 34: ...by incoming call 11 21 38 xx xx period sec between switches 1 and 2 closing 10 41 v choice type v tone pulse 0 42 z sign for call extension 43 g bb command for guard hanging up from phone 155 266 44...

Страница 35: ...00ms 50 p pause duration interdigit gap 8 800ms 8 basic setting executes 81 deletes all numbers in group 1 Day mode 82 deletes all numbers in group 2 Night mode 83 basic setting only for parameters 3x...

Страница 36: ...DTMF sign of call extension hanging up from phone 1 2 55 66 service password 0000 switching to day mode 11 switching to night mode 10 guard choice mode Day Night keyboard connection no keyboard mode d...

Страница 37: ...and width 300Hz 3400 Hz 20 60mA Impedance of ringing 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse choice 40 60 ms Tone choice level 4 a 6 dB 20 60 mA Tone choice sensitivity 40 dB...

Страница 38: ...1gr 106 16 Number under button 7 Day 1gr 107 16 Number under button 8 Day 1gr 108 16 Number under button 9 Day 1gr 109 16 Number under button 10 Day 1gr 110 16 Number under button 11 Day 1gr 111 16 N...

Страница 39: ...losing sec 38 2 Tone pulse tone choice 1 0 41 1 Sign of call extension 42 1 Guard hang up from phone 1 431 2 Guard hang up from phone 2 432 2 Service password 44 4 Comm to DAY switching 45 2 Comm to N...

Страница 40: ...Pause durat interdigit gap nx100 50 ms 1...

Страница 41: ...producer only will make the guarantee repairs Attach the description of claim reason proof of purchase and your exact address to the product The guarantee does not include mechanical thermal chemical...

Страница 42: ...JR 2010 version V8 1 IV 10...