3.2 General Settings
BLOCK
: Block number the 1W panel, between 001 and 999 (default option 1).
APARTMENT
: Apartment number communicates with 1W panel, between 0001 and 9899
(default option 101).
DEVICE NO.
: Panel Number, between 1 and 9 (default option 1).
TYPE:
1W PANEL.
LANGUAGE
: Select the desired language for the drop-down options (default option ENGLISH).
Refresh the webpage after change the language.
PANEL VOLUME
: Select the desired value between 1 and 6, (default option 4).
The conversation volume is common for uplink and downlink.
VIDEO RESOLUTION
: In order to fit the different types of monitor. The default value 640×480
is to be used usually.
SIP DIVERT MODE
: (this feature may not be available at the time of releasing the manual)
PARALLEL CALL:
When the panel calls the resident, the monitor and the call divert APP ring
at the same time. Once one terminal answers the call the other one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring about 30s if no
answer, the call divert APP will start to ring.
DATE FORMAT
: Date format.
DATE
: Setting the date of panel.
TIME
: Setting the time of panel.
TIME ZONE
: Setting the time zone of panel.
Select local time zone and save.
If the project has no management software the installer can set date, time and time zone
manually. If the project has management software, the date and time of panel will synchronizes
automatically with the management software. If the panel has access to internet, the date and
time of panel will also synchronize with internet time server.
NOTE
:
Do not use TIME ZONE setting if panel is connected to Internet or Management Software.
Date and time can’t be saved after power loss, the time zone and date format can be saved.