CONFIGURING AS MASTER PANEL
HOW TO PROGRAM THE VEO MONITOR
Press the SW1
button 3 consecutive times quickly. After 2 seconds, a con
fi
rmation tone is heard, and
the master
panel
is activated. Once having completed the monitor´s programming, we recommend
deactivate the MASTER
panel by pressing the SW1
button 3 consecutive times.
Monitor powered for the
fi
rst time.
The red led blinking rapidly indicates that the monitor has not been
programmed. The fi xed red led indicates that the monitor has been
programmed.
1. INSTALL
Press the
button to access the "programming menu."
2. ENTER PROGRAMMING MENU
PROGRAMMING MENU
PROGRAMMING
FROM THE PANEL
Code 970160 V03_20
Inductive loop
label (depending on the model)
Digital menu for internal parameter settings and confi guration.
(When the monitor has already been programmed)
In conversation, press to open the door.
In standby, call to guard unit (if applicable).
Auxiliary function, (contact your installer).
In standby, press and it displays the option of auto-on with
different panels. By sequentially pressing Panel 0, Panel 1,
General Panel, (depending on the available panels).
F2
99
VEO monitor incorporates an OSD menu that is managed via the
monitor´s push buttons. The icons displayed are managed with
the corresponding buttons located on the monitor.
The white line at the bottom of the icon indicates the function that is currently in effect.
Select with
/
the desired icon and confi rm with
.
Select the
icon and confi rm with
, (you hear a beep in the monitor).
Enter the calling code for this monitor from the panel (calling code for this monitor). A different
call tone sounds, confi rming the monitor´s programming. After a few seconds the monitor returns
to standby.