Ferm FCD-2400 Скачать руководство пользователя страница 2

Ferm

7

FERM COMBIDRILL FCD-2400 1 2
USERS MANUAL

TECHNICAL SPECIFICATIONS

PACKAGE CONTENTS

1 Cordless drill
2 Batteries
1 Battery charger
2  Double sided bits
1 Case
1 Users manual
1 Safety instructions
1 Guarantee 

card

Check the machine, loose parts and accessories for
transport damage.

PRODUCT INFORMATION

1 Direction switch
2 On/off switch
3 Torque setting ring
4 Impact sleeve
5 Chuck
6 Battery

SAFETY INSTRUCTIONS

The following pictograms are used in these instructions
for use:

Denotes risk of personal injury, loss of life or
damage to the tool in case of non-observance of the

instructions in this manual.

Denotes risk of electric shock.

Carefully read this manual before using the machine. Make
sure that you know how the machine functions and how to
operate it. Maintain the machine in accordance with the
instructions to make sure it functions properly. Keep this
manual and the enclosed documentation with the machine.

Ferm products are manufactured to high quality standards
they are safe and fit for purpose at time of sale, but all tools
can be dangerous if the correct precautions are not taken.
Always follow these instructions, do not carry out the ope-
ration until you are sure you can do so in safety. Remember
to consider the work environment for safe operation as well
as safety for tool use. 

Warning! When using electric tools, basic safety
precautions should always be followed to reduce

the risk of fire, electric shock and personal injury. Read all
these instructions before attempting to operate this product.
Save these instructions for future reference.

PERSONAL SAFETY
Use Personal Protection Safety Equipment 

Protect eyes with safety glasses or goggles note: the use
of safety protective eyewear without the CE mark can
lead to serious injury if the lens breaks. A suitable dust
mask should be worn if cutting; drilling or sanding is
dusty, in particular chipboard or MDF. 
Approved safety footwear and headgear should worn as
appropriate, for example on building works or when
heavy weights are involved. Wear a suitable  apron to
protect against sparks/debris. Wear earplugs or ear
defenders. 

Dress properly

Do not wear loose clothing or jewellery. It can get caught
in moving parts. Non-skid footwear is recommended
when working out doors. Wear protective hair covering
to contain long hair

Stay alert

Watch what you are doing Use common sense. Do not
operate tools when tired or after taking alcohol or pre-
scription/ non-prescription drugs.

2

3

4

5

1

1

2

3
4

5

6

Voltage | 24 

V

Voltage battery charger

| 230 V~

Frequency battery charger

| 50 Hz

Capacity battery 

| 1.2 Ah (NiCd)

Charging time

| 1 h

Speed, no load

| 0 - 900/min

Impact frequency

| 0 - 16200/min

Machine weight (incl. 1 battery)

| 2.5 kg

Lpa Sound pressure level

| 91.3 dB(A)

Lwa Sound power level

| 104.3 dB(A)

Vibration

| 7 m/s

2

2

Ferm

EXPLODED VIEW

SPARE PARTS LIST FCD-2400 I 2

REF NR.

DESCRIPTION

FERM NR.

3

SWITCH

406654

4

FCD-2400 I B BATTERY

718791

11

DRILL CHUCK

406516

12

LEFT BOLT DRILL CHUCK

406403

29

LEFT / RIGHT BUTTON

406656

-

CHARGER FCD-2400 I C

406517

Содержание FCD-2400

Страница 1: ... 0306 03 FermCombidrillwith Impactfunction FCD 2400I2 USER SMANUAL Art nr 718790 Screwfixart nr19323 UK Subjecttochange DocumentRef FCD240012 19323 PMR6 issue1 Mar02 Copyright TheseinstructionsarethesolepropertyofFerm OmegaToolsandmaynotbereproduced ...

Страница 2: ...the risk of fire electric shock and personal injury Read all these instructions before attempting to operate this product Savetheseinstructionsforfuturereference PERSONALSAFETY UsePersonalProtectionSafetyEquipment Protect eyes with safety glasses or goggles note the use of safety protective eyewear without the CE mark can lead to serious injury if the lens breaks A suitable dust mask should be wor...

Страница 3: ...or use them in damp or wet locations Keep work area well lit Do not use power tools in the presence of flammable liquids vapoursorgases Guardagainstelectricshock Thisunitanditschargercontaindangerousvoltages Use a RCD residual current device to provide protection against electrical shock Prevent body contact with groundedsurfaces e g pipes radiator rangesorrefrige rators Keepchildrenandpetsaway Do...

Страница 4: ... them repaired by a qualified person or authorised service body Keep handles free from oil or grease Keep theventilationslotscleantopreventmotoroverheating Checkfordamagedparts Donotuseatoolwithdamagedparts beforefurtheruse a damaged tool must be carefully checked by a qualified person to determine that it will operate properly Check for alignment of moving parts binding or breakage of parts mount...

Отзывы: