SERIES 35-62

24 VAC Microprocessor Based Dual Point 
Direct Spark Ignition Control

FEATURES

 

24 VAC microprocessor based DSI control

 

System diagnostic LED

 

Multiple tries

 

Custom prepurge and interpurge timings

 

Remote flame sensing

 

Full time flame sensing

 

Flame sense test pins

 

Software conforms to UL 1998 requirements

DESCRIPTION

The Series 35-62 is a 24 VAC Microprocessor Based Dual Point
Direct Spark Ignition Control continually and safely monitors, 
analyzes and controls the proper operation of two gas burners.
Value added features such as LED diagnostics, automatic one hour
reset, and flame current test pins highlight the controls benefits.

®

35.62.03

Input Power

Control:20-28 VAC 50/60 Hz
(Class 2 Transformer)

Input Current Drain

300 mA @ 24 VAC and
gas valve relay energized
(control only)

Gas Valve Rating

1.5A @ 24 VAC
(Inrush 3,0A maximum)

Operating Temperature

-40°F to +160°F
-40°C to +71°C

Flame Sensitivity

>1.0uA minimum

Flame Failure

0.8 seconds

Response Time

Types of Gases

Natural, LP, or manufactured

Spark Rate

Line frequency
(50/60 sparks/sec)

Enclosure

Gray (Noryl N-190) fire
retardant plastic integral
standoffs optional

Moisture Resistance

Conformal coated to operate
to 95% R.H. Care must be
taken to protect module from
direct exposure to water

Tries for Ignition

One or three try versions
available

Trial for Ignition Periods

4.0,7.0,10.0,15.0 or 21.0
seconds available

Prepurge & Interpurge

None,15, or 30 seconds
depending on model.

APPLICATIONS

 

Gas furnaces

 

Boilers

 

Water heaters

 

Commercial cooking

 

Other similar appliances

SPECIFICATIONS

Series 35-62, 24 VAC Dual Point DSI Control

Page 1

www.fenwalcontrols.com

1-800-FENWAL-1

Agency Certifications

Design certified to ANSI Z21.20-1993 and

CAN/CSA C22.2 No. 199-M89

Содержание 35-62 Series

Страница 1: ...e relay energized control only Gas Valve Rating 1 5A 24 VAC Inrush 3 0A maximum Operating Temperature 40 F to 160 F 40 C to 71 C Flame Sensitivity 1 0uA minimum Flame Failure 0 8 seconds Response Time Types of Gases Natural LP or manufactured Spark Rate Line frequency 50 60 sparks sec Enclosure Gray Noryl N 190 fire retardant plastic integral standoffs optional Moisture Resistance Conformal coated...

Страница 2: ...respond within 0 8 seconds The HV spark will be energized for a trial for ignition period in an attempt to relight the burners If either burner does not light the control will de energize the gas valve Multi try models will make two more attempts to relight the burners If either burner does not relight the control will go into lockout as noted above in Failure to light If flame is re established n...

Страница 3: ...kay during TFI A Bad electrode no flame sense after TFI B Bad S1 or HV wire C Poor ground at burner D Poor flame check flame current 6 Flame with no call for heat A Stuck valve check LED for 2 flashes FLAME CURRENT CHECK Flame current is the current which passes through the flame from the sensor to ground The minimum flame current necessary to keep the system from lockout is 7 microamps To measure...

Страница 4: ...rovide for every possible contingency to be met in connection with installation operation and maintenance All specifications subject to change without notice Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to KIDDE FENWAL Inc Ashland Massachusetts P N 35 62 03 10 30 03 Page 4 Ser...

Отзывы: