background image

Quick Installation Manual (ENG)

Watts V25 - PLUG-IN 

1x

1x

INST

ALLA

TION

MANUAL

1.

 Presentation

- The V25 receiver is a plug mounting receiver, specially designed to control an
electrical radiator regulation in combination with a wireless thermostat V22 type.
- This couple (Thermostat - Receiver) can also be managed by a Central V24 to 
have a full control of your heating installation from one point.
- The V25 receiver can be used as slave unit of a V23 receiver.
- There is a possibility to use the V25 receiver as On/Off Timer in combination with a 
V24 Central unit.
Make sure that all components of the wireless regulation system are marked with
the Fenix logo (description).
A combination with wireless products from different suppliers isn´t possible!

Box content

Install and plug the receiver into the following guidelines to guarantee an optimal reception:

- The receiver must be put at a minimum distance of 50cm of all others electrical or wireless materials like GSM, Wi-Fi router.
- Before wiring work related to the receiver must be carried out only when de-energized
- Connect your receiver to the power supply.

In order to maintain the correct installation of RF initialisation you need to follow next steps.
Installation 1: Re RF thermostat

1. 

The receiver V25 must be put in OFF by pressing on the ON/OFF button

2. 

The receiver must be put in RF init mode by 2-10sec pressing on the ON/OFF Button.

 

3. 

Then the RF LED should flashes Red/Green indicating that the Receiver is now in radio configuration mode 

waiting for a thermostat configuration address. 

4.

 

Please refer to the thermostat leaflet 

to

 enter the thermostat in “RF Init” mode. 

5. The receiver RF LED must 

become to be solid green, then change to off position or heating position, it depends on thermostat set temperature. T

hermostat 

should exit the RF init mode to indicate correct paring between both elements

.

Installation 2: Re RF Ther RF Central 

 

1.

Make the “Installation 1” rules for pairing with the thermostat. 

2. 

The receiver must be put one time more in RF init mode by 

2-10 

sec pressing on the 

On/Off 

Button. 

3. 

Then the RF LED 

button

 should

 flashes Green and Red 

indicating that the Receiver is now in radio

 

configuration mode waiting for a thermostat

 or V24

 

configuration address. 

4. 

Please refer to the Central

 unit

 leaflet for more explanation about the pairing mode “RF Init”. 

5. 

The receiver RF LED must 

become to be solid green, then change to off position or heating position, it depends on thermostat set temperature. T

he Central 

unit 

will show a message to indicate correct paring between both elements

.

TECHNOLOGY CHARACTERISTICS

N898_R00 (13.03.2023)

Switch the outlet ON/OFF

Pairing a socket with a Thermostat V22 and a Central unit V24 WIFI

Pairing a socket with a receiver (V23 - V26 master)

Reset the socket to a factory settings

1 sec 

2-10 sec 

2-10 sec 

10+ sec 

The LED will turn BLUE

LED flashes RED and GREEN

LED flashes BLUE and GREEN

The LED flashes GREEN and then 

CONTROL FUNCTIONS FROM OUTLET - OFF POSITION

flashes 1x RED, GREEN, BLUE

Switching between pairing the outlet with the thermostat and the receiver is done by pressing the flashing 
control button on the socket.

   

Switching between pairing the outlet with the thermostat and the receiver is done by pressing the flashing 
control button on the socket.

   

2-10 sec 

LED flashes BLUE

CONTROL FUNCTIONS FROM THE SOCKET - 

ON POSITION

Booster - Timer (default value 2h)

INLET

OUTLET

LED 

POWER BUTTON

Smart wireless socket receiver

You will need the central Unit V24 and the Fenix 
V24  WIFI  Mobile  app  to  control  this  socket 
remotely. Only the Fenix V24 modular system is 
compatible with this connection.

Содержание Watts V25 PLUG-IN

Страница 1: ...ujte a zapojte přijímač dle následujících pokynů Přijímač musí být umístěn ve vzdálenosti minimálně 50 cm od veškerých jiných elektrických a bezdrátových zařízení jako je GSM Wi Fi router Zapojte přijímač do zásuvky Pro správnou inicializaci RF je nutné dodržet následující postup Kombinace 1 Přijímač termostat RF 1 Přijímač V25 musí být přepnut na VYPNUTO stisknutím tlačítka ZAPNUTO VYPNUTO 2 Přij...

Страница 2: ...rávně spárovány Poznámka 1 Tímto způsobem bude přijímač V25 pracovat v režimu Časovač budete mít možnost vytvořit týdenní program ZAPNUTO VYPNUTO V této konfiguraci můžete přidat 3 závislé jednotky V25 Poznámka 2 V případě instalace s termostatem V22 a ztrátou RF komunikace RF Alarm přijímač po 2 hodinách přeruší napájení a začne blikat zeleně aby signalizoval ztrátu signálu KOMBINACE 1 KOMBINACE 2...

Страница 3: ...off position or heating position it depends on thermostat set temperature Thermostat should exit the RF init mode to indicate correct paring between both elements Installation 2 Receiver RF Thermostat RF Central 1 Make the Installation 1 rules for pairing with the thermostat 2 The receiver must be put one time more in RF init mode by 2 10 sec pressing on the On Off Button 3 Then the RF LED button sh...

Страница 4: ... will work in aTimer mode you will have the possibility to create a weekly program for ON OFF period You can also add 3 slaves V25 receiver units in this configuration Note 2 In case of installation with V22 thermostat and loss of RF communication RF Alarm the receiver V25 will after 2 Hours cut off the power supply and start flashing in Green to indicate a signal was lost INSTALLATION 1 INSTALLATION...

Отзывы: